Static error in the temperature constant measurement configurations due to DC amplifier offset voltage

R. Freire, F. Santos, R.N.C. Alves, A. T. Barros, B. Luciano
{"title":"Static error in the temperature constant measurement configurations due to DC amplifier offset voltage","authors":"R. Freire, F. Santos, R.N.C. Alves, A. T. Barros, B. Luciano","doi":"10.1109/IMTC.2003.1208021","DOIUrl":null,"url":null,"abstract":"The DC amplifier offset voltage introduces dynamic and static errors in measurements based on heated sensors at constant temperature configuration. It is shown, in the case of a radiometer, the variation of static errors in function of offset voltage for configurations of feedback based on analogic voltage control and on pulse width modulation - PWM. These errors increase with offset voltage and are similar in PWM configuration, decreasing with pulse amplitude.","PeriodicalId":135321,"journal":{"name":"Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 20th IEEE Instrumentation Technology Conference (Cat. No.03CH37412)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2003.1208021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The DC amplifier offset voltage introduces dynamic and static errors in measurements based on heated sensors at constant temperature configuration. It is shown, in the case of a radiometer, the variation of static errors in function of offset voltage for configurations of feedback based on analogic voltage control and on pulse width modulation - PWM. These errors increase with offset voltage and are similar in PWM configuration, decreasing with pulse amplitude.
温度常数测量配置中的静态误差是由直流放大器偏置电压引起的
直流放大器偏置电压在基于恒温配置的加热传感器的测量中引入了动态和静态误差。以辐射计为例,显示了基于模拟电压控制和脉宽调制的反馈配置的静态误差随偏置电压的变化。这些误差随偏置电压的增加而增加,在PWM配置中相似,随脉冲幅度的增加而减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信