Carbon Monoxide Concentrations in Kitchens of Gas-fired Burners, Karachi, Pakistan

Z. Shams, T. Javed, A. Zubair, M. Waqas, S. Ali, Anusha Ahmed
{"title":"Carbon Monoxide Concentrations in Kitchens of Gas-fired Burners, Karachi, Pakistan","authors":"Z. Shams, T. Javed, A. Zubair, M. Waqas, S. Ali, Anusha Ahmed","doi":"10.52763/pjsir.phys.sci.65.1.2022.25.32","DOIUrl":null,"url":null,"abstract":"In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.","PeriodicalId":228754,"journal":{"name":"Pakistan Journal of Scientific &amp; Industrial Research Series A: Physical Sciences","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Journal of Scientific &amp; Industrial Research Series A: Physical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52763/pjsir.phys.sci.65.1.2022.25.32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.
煤气燃烧器厨房的一氧化碳浓度,卡拉奇,巴基斯坦
在这项研究中,使用固定式室内一氧化碳(CO)监测仪对54间平房和25间公寓的燃气厨房进行了研究。使用EL-USB-CO300数据记录仪以1分钟分辨率测量每个厨房内24小时的CO水平。每小时,8小时和24小时,计算所有厨房的CO平均值。平房厨房每小时和24小时的CO平均值分别为3.72±6.26 ppm和3.72±3.16 ppm,而公寓厨房的CO平均值分别为3.74±6.96 ppm和3.74±2.17 ppm。平房厨房8 h CO均值夜间、白天和晚上分别为2.62±3.22 ppm、4.85±4.66 ppm和3.53±3.30 ppm,公寓厨房8 h CO均值分别为2.13±2.02 ppm、3.79±3.86 ppm和5.29±4.17 ppm。平房与公寓夜间8 h CO浓度的平均差异为1.76±0.87 ppm (P<0.01)。20%的厨房公寓和16.67%的平房超过了世界卫生组织的每日接触限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信