Uniform field breakdown in SF/sub 6/ gas at high pressures under lightning and switching surge voltages

B. S. Manjunath, K. Dwarakanath, K.S. Arunachala Sastry, K. Ravi
{"title":"Uniform field breakdown in SF/sub 6/ gas at high pressures under lightning and switching surge voltages","authors":"B. S. Manjunath, K. Dwarakanath, K.S. Arunachala Sastry, K. Ravi","doi":"10.1109/CEIDP.1988.26353","DOIUrl":null,"url":null,"abstract":"Experiments were conducted to determine the 50% flashover voltages (V/sub 50/) over the pressure range of 0.14 to 0.45 MPa absolute, using lightning (1.2/50 mu s) and switching (100/2500 mu s) impulse voltages, under uniform electric fields having two electrodes of Rogowski profile, with a gap spacing varying from 4 to 30 mm. Results indicate that the breakdown strength of SF/sub 6/ gas exhibits slight saturation at higher pressures (above 0.3 MPa). The effect is higher for switching surge voltages than for impulse voltages. The polarity effect is observed both under lightning and switching surge voltages and is more pronounced at higher gas pressures and larger gap spacings. The V/sub 50/ values with switching surge voltages are generally lower than the corresponding lightning impulse voltage values.<<ETX>>","PeriodicalId":149735,"journal":{"name":"1988. Annual Report., Conference on Electrical Insulation and Dielectric Phenomena","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1988. Annual Report., Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1988.26353","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Experiments were conducted to determine the 50% flashover voltages (V/sub 50/) over the pressure range of 0.14 to 0.45 MPa absolute, using lightning (1.2/50 mu s) and switching (100/2500 mu s) impulse voltages, under uniform electric fields having two electrodes of Rogowski profile, with a gap spacing varying from 4 to 30 mm. Results indicate that the breakdown strength of SF/sub 6/ gas exhibits slight saturation at higher pressures (above 0.3 MPa). The effect is higher for switching surge voltages than for impulse voltages. The polarity effect is observed both under lightning and switching surge voltages and is more pronounced at higher gas pressures and larger gap spacings. The V/sub 50/ values with switching surge voltages are generally lower than the corresponding lightning impulse voltage values.<>
SF/sub - 6/气体在雷电和开关浪涌电压高压下的均匀场击穿
在Rogowski型两电极间距为4 ~ 30 mm的均匀电场条件下,采用闪电(1.2/50 μ s)和开关(100/2500 μ s)冲击电压,在0.14 ~ 0.45 MPa绝对压力范围内确定50%闪络电压(V/sub 50/)。结果表明:在较高压力下(大于0.3 MPa), SF/sub - 6/ gas的击穿强度呈现轻微饱和;开关浪涌电压比脉冲电压的影响更大。极性效应在雷电和开关浪涌电压下都可以观察到,在较高的气体压力和较大的间隙下更为明显。开关浪涌电压的V/sub /值一般低于相应的雷击电压值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信