Time-Domain EMI Measurements using a Low Cost Digitizer to Optimize the Total Measurement Time for a Test Receiver

Tom Hartman, R. Grootjans, N. Moonen, F. Leferink
{"title":"Time-Domain EMI Measurements using a Low Cost Digitizer to Optimize the Total Measurement Time for a Test Receiver","authors":"Tom Hartman, R. Grootjans, N. Moonen, F. Leferink","doi":"10.1109/EMCEUROPE48519.2020.9245801","DOIUrl":null,"url":null,"abstract":"By analyzing electromagnetic interference (EMI) based on its spectral components important time-domain information is lost. Conventional super-heterodyne frequency band stepping EMI test receivers have to use long dwell times for every frequency which makes the total measurement time too long. Often dwell times are set too short, causing time-varying interference, or cyclo-stationary interference, to be detected improperly. The concept of time-varying EMI is also not incorporated in standards, which are only based on frequency domain limits. To catch these time-varying interferences the receiver has to measure for at least one repetition period. Measuring many spectral components for at least the repetition of a cyclo-stationary signal causes detrimental measurement times. Time-domain electromagnetic interference (EMI) analyzers have been proposed to reduce these long measurement times, but remain expensive. To reduce costs the utilization of time-domain EMI measurements using a low cost digitizer is examined. A PicosScope in conjunction with Digital Signal Processing (DSP) is used to create the possibility to estimate the total measurement time of a conventional EMI receiver based on the dwell times. This can be used to optimize the total measurement time needed for the test receiver, while still complying to standards, resulting in reduced measurement times otherwise needed in expensive test labs. A short-time Fast-Fourier transform (STFFT) is used to examine the interfering source in both frequency and time simultaneously. It was also shown that the conventional EMI receiver perceives certain time varying signals as continuous waves due to the spectral nature of this receiver.","PeriodicalId":332251,"journal":{"name":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE48519.2020.9245801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

By analyzing electromagnetic interference (EMI) based on its spectral components important time-domain information is lost. Conventional super-heterodyne frequency band stepping EMI test receivers have to use long dwell times for every frequency which makes the total measurement time too long. Often dwell times are set too short, causing time-varying interference, or cyclo-stationary interference, to be detected improperly. The concept of time-varying EMI is also not incorporated in standards, which are only based on frequency domain limits. To catch these time-varying interferences the receiver has to measure for at least one repetition period. Measuring many spectral components for at least the repetition of a cyclo-stationary signal causes detrimental measurement times. Time-domain electromagnetic interference (EMI) analyzers have been proposed to reduce these long measurement times, but remain expensive. To reduce costs the utilization of time-domain EMI measurements using a low cost digitizer is examined. A PicosScope in conjunction with Digital Signal Processing (DSP) is used to create the possibility to estimate the total measurement time of a conventional EMI receiver based on the dwell times. This can be used to optimize the total measurement time needed for the test receiver, while still complying to standards, resulting in reduced measurement times otherwise needed in expensive test labs. A short-time Fast-Fourier transform (STFFT) is used to examine the interfering source in both frequency and time simultaneously. It was also shown that the conventional EMI receiver perceives certain time varying signals as continuous waves due to the spectral nature of this receiver.
使用低成本数字化仪进行时域EMI测量以优化测试接收机的总测量时间
电磁干扰的频谱分析会丢失重要的时域信息。传统的超外差频段步进电磁干扰测试接收机必须对每个频率使用较长的驻留时间,这使得总测量时间过长。通常,停留时间设置得太短,导致时变干扰或循环平稳干扰被不正确地检测到。时变电磁干扰的概念也没有纳入标准,这些标准仅基于频域限制。为了捕捉这些时变干扰,接收机必须测量至少一个重复周期。为了至少重复一个周期平稳信号而测量多个频谱分量会导致有害的测量时间。时域电磁干扰(EMI)分析仪被提出来减少这些长时间的测量时间,但仍然昂贵。为了降低成本,研究了使用低成本数字化仪进行时域电磁干扰测量的方法。PicosScope与数字信号处理(DSP)结合使用,可以根据停留时间估计传统EMI接收器的总测量时间。这可以用于优化测试接收器所需的总测量时间,同时仍然符合标准,从而减少昂贵的测试实验室所需的测量时间。采用短时快速傅立叶变换(STFFT)对干扰源进行频率和时间检测。还表明,由于该接收器的频谱性质,传统的EMI接收器将某些时变信号视为连续波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信