Data circuit surge protection

F.A. Larmier
{"title":"Data circuit surge protection","authors":"F.A. Larmier","doi":"10.1109/INTLEC.1990.171266","DOIUrl":null,"url":null,"abstract":"Sources of overvoltage surges posing threats to digital equipment are discussed. The ideal protection for data circuits must have high discharge capacity, fast response time, precise clamping voltage, and be almost transparent on the line. Those characteristics are obtained with hybrid circuitry which is made of a gas tube on the input stage and a diode on the output stage. Once the surge passes the primary protector without being stopped, it is clamped down by the solid state diode first, and then the bulk of the energy (99%) is handled by the gas tube. The diode provides a response time in the range of 1 nanosecond. It handles only 1% of the total energy dissipated. The diode must have a tight clamping ratio in order to reduce as much as possible the risk window. Location of the data circuit surge protector and installation precautions are discussed.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on Telecommunications Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1990.171266","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Sources of overvoltage surges posing threats to digital equipment are discussed. The ideal protection for data circuits must have high discharge capacity, fast response time, precise clamping voltage, and be almost transparent on the line. Those characteristics are obtained with hybrid circuitry which is made of a gas tube on the input stage and a diode on the output stage. Once the surge passes the primary protector without being stopped, it is clamped down by the solid state diode first, and then the bulk of the energy (99%) is handled by the gas tube. The diode provides a response time in the range of 1 nanosecond. It handles only 1% of the total energy dissipated. The diode must have a tight clamping ratio in order to reduce as much as possible the risk window. Location of the data circuit surge protector and installation precautions are discussed.<>
数据电路浪涌保护
讨论了对数字设备构成威胁的过电压浪涌的来源。理想的数据电路保护必须具有高放电容量,快速响应时间,精确的箝位电压,并且在线上几乎是透明的。这些特性是由输入级的气管和输出级的二极管组成的混合电路获得的。一旦浪涌通过初级保护器而不被阻止,它首先被固态二极管压制,然后大部分能量(99%)由气体管处理。二极管提供1纳秒范围内的响应时间。它只能处理总耗散能量的1%。二极管必须有一个紧夹比,以便尽可能地减少风险窗口。讨论了数据电路防雷器的位置和安装注意事项
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信