{"title":"Fearures of the Mathematical Modeling of Frequency Converters with Active Rectifiers for Power Quality Analysis in Internal Power Supply Systems","authors":"A. Nikolaev, I. Gilemov, L. Antropova","doi":"10.1109/EIConRus49466.2020.9038988","DOIUrl":null,"url":null,"abstract":"The work presents a comparative assessment of two models of a frequency converter with an active rectifier from the position of their influence on the supply network. In the first model, the frequency converter was fully simulated, in the second - an inverter and the synchronous motor were replaced by a current source. For research, two simulation models of a frequency converter with a three-level active rectifier, made according to a 12-pulse circuit, were developed and implemented in the Matlab-Simulink program. The harmonic composition of the consumed current and mains voltage at the connection point of the frequency converter is investigated. The conclusion is drawn about the possibility of simplified modeling of a frequency converter with an active rectifier analyzing the power quality in internal power supply systems of industrial enterprises.","PeriodicalId":333365,"journal":{"name":"2020 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIConRus49466.2020.9038988","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The work presents a comparative assessment of two models of a frequency converter with an active rectifier from the position of their influence on the supply network. In the first model, the frequency converter was fully simulated, in the second - an inverter and the synchronous motor were replaced by a current source. For research, two simulation models of a frequency converter with a three-level active rectifier, made according to a 12-pulse circuit, were developed and implemented in the Matlab-Simulink program. The harmonic composition of the consumed current and mains voltage at the connection point of the frequency converter is investigated. The conclusion is drawn about the possibility of simplified modeling of a frequency converter with an active rectifier analyzing the power quality in internal power supply systems of industrial enterprises.