[The use of the T-Scan system in occlusal diagnosis].

A Dees, K Kess, P Proff, S Schneider
{"title":"[The use of the T-Scan system in occlusal diagnosis].","authors":"A Dees,&nbsp;K Kess,&nbsp;P Proff,&nbsp;S Schneider","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The present study examines the T-Scan reproduction system used in occlusal diagnosis. The system represents a major technical innovation in functional diagnostics. Nevertheless, various aspects of it still require improvement. Amplifying or confirming the results of previous studies, the following observations are intended to indicate how the system might be improved, and how it can be reliably used at present: The reproduction afforded by the sensor as situated in the mouth is insufficient. Exact reproduction of the topography of the occlusal contacts is not possible. Reproducibility of the temporal sequence of the contacts is slight. The registering of dental functional movements can give rise to errors of interpretation. Threshold values for the registration of contact points in the system's pressure mode are uneven. The relative reproduction of different impressions is unreliable. Since in the system's pressure-mode early contacts cannot be distinguished from strong physiological contacts, in clinical practice the former must first be identified using the time-mode.</p>","PeriodicalId":77104,"journal":{"name":"Deutsche Zahn-, Mund-, und Kieferheilkunde mit Zentralblatt","volume":"80 3","pages":"145-51"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche Zahn-, Mund-, und Kieferheilkunde mit Zentralblatt","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present study examines the T-Scan reproduction system used in occlusal diagnosis. The system represents a major technical innovation in functional diagnostics. Nevertheless, various aspects of it still require improvement. Amplifying or confirming the results of previous studies, the following observations are intended to indicate how the system might be improved, and how it can be reliably used at present: The reproduction afforded by the sensor as situated in the mouth is insufficient. Exact reproduction of the topography of the occlusal contacts is not possible. Reproducibility of the temporal sequence of the contacts is slight. The registering of dental functional movements can give rise to errors of interpretation. Threshold values for the registration of contact points in the system's pressure mode are uneven. The relative reproduction of different impressions is unreliable. Since in the system's pressure-mode early contacts cannot be distinguished from strong physiological contacts, in clinical practice the former must first be identified using the time-mode.

【t扫描系统在咬合诊断中的应用】。
本研究探讨了用于咬合诊断的t扫描复制系统。该系统是功能诊断领域的一项重大技术创新。然而,它的许多方面仍然需要改进。放大或确认先前研究的结果,以下观察旨在表明该系统如何改进,以及目前如何可靠地使用:位于口腔中的传感器提供的再现不足。咬合接触地形的精确再现是不可能的。接触时间序列的重现性很弱。对牙齿功能运动的记录会引起解释的错误。系统压力模式下接触点配准的阈值不均匀。不同印象的相对再现是不可靠的。由于在系统的压力模式下,早期接触不能与强烈的生理接触区分开来,在临床实践中,前者必须首先使用时间模式来识别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信