Group delay and phase measurements at converters and multistage converters without LO access

Thilo Bednorz
{"title":"Group delay and phase measurements at converters and multistage converters without LO access","authors":"Thilo Bednorz","doi":"10.1109/COMCAS.2009.5386030","DOIUrl":null,"url":null,"abstract":"This paper describes a new technique that allows group delay and relative phase measurements of frequency converters and mixers that don't have access to the local oscillator or the reference signal. In contrast to the methods offered by network analyzers in the past, the measurement accuracy of this technique is independent of the frequency and phase stability of the internal local oscillator of the DUT. The key of this new method is, that the DUT is stimulated with an nearly arbitrary two-tone signal. The phase difference between these two carriers is measured at the input and the output of the DUT to derive the group delay and the relative phase of the conversion loss of the DUT.","PeriodicalId":372928,"journal":{"name":"2009 IEEE International Conference on Microwaves, Communications, Antennas and Electronics Systems","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Conference on Microwaves, Communications, Antennas and Electronics Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMCAS.2009.5386030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper describes a new technique that allows group delay and relative phase measurements of frequency converters and mixers that don't have access to the local oscillator or the reference signal. In contrast to the methods offered by network analyzers in the past, the measurement accuracy of this technique is independent of the frequency and phase stability of the internal local oscillator of the DUT. The key of this new method is, that the DUT is stimulated with an nearly arbitrary two-tone signal. The phase difference between these two carriers is measured at the input and the output of the DUT to derive the group delay and the relative phase of the conversion loss of the DUT.
在没有LO接入的变换器和多级变换器上进行群延迟和相位测量
本文介绍了一种新的技术,可以在没有本地振荡器或参考信号的情况下测量变频器和混频器的群延迟和相对相位。与以往网络分析仪提供的方法相比,该技术的测量精度与被测设备内部本振的频率和相位稳定性无关。这种新方法的关键是用几乎任意的双音信号来刺激被测体。在DUT的输入和输出处测量这两个载波之间的相位差,从而推导出DUT的群延迟和转换损耗的相对相位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信