{"title":"Power Plant Heating 6kv Fc Switch Anti-Jump Control Circuit Optimization","authors":"Gong Xiuzhong, Xu Xizhi, L. Shifu, Mao Qingbo, Zhang Chao, Xun Lei, Wang Yongqiang","doi":"10.1109/icsgea.2019.00011","DOIUrl":null,"url":null,"abstract":"High-pressure vacuum contactor is an important primary equipment for high-voltage power plant system in power plants. It has the advantages of low noise, long service life and frequent operation. It is mainly used for the control of high-voltage motors in factories. If the switch is repeatedly switched on and off, it will cause great impact force on the stator coil and rotor squirrel cage bar of the motor, and damage the insulation of the winding and cause overheating and fracture of the squirrel cage bar. At the same time, it may also cause bus grounding, damage or even explosion of the switch contacts. Therefore, it is necessary to analyze and discuss the fault causes of the anti-jump control loop of the high-voltage vacuum contactor of the power plant, and seek to solve the \"anti-jump\" scheme. The control loop is optimized by analysis to solve the fault, and technical support is also provided for the anti-jump circuit of the 6kV vacuum switch and the FC switch.","PeriodicalId":201721,"journal":{"name":"2019 International Conference on Smart Grid and Electrical Automation (ICSGEA)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Smart Grid and Electrical Automation (ICSGEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icsgea.2019.00011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High-pressure vacuum contactor is an important primary equipment for high-voltage power plant system in power plants. It has the advantages of low noise, long service life and frequent operation. It is mainly used for the control of high-voltage motors in factories. If the switch is repeatedly switched on and off, it will cause great impact force on the stator coil and rotor squirrel cage bar of the motor, and damage the insulation of the winding and cause overheating and fracture of the squirrel cage bar. At the same time, it may also cause bus grounding, damage or even explosion of the switch contacts. Therefore, it is necessary to analyze and discuss the fault causes of the anti-jump control loop of the high-voltage vacuum contactor of the power plant, and seek to solve the "anti-jump" scheme. The control loop is optimized by analysis to solve the fault, and technical support is also provided for the anti-jump circuit of the 6kV vacuum switch and the FC switch.
电厂供热6kv光纤开关防跳控制电路优化
高压真空接触器是电厂高压电厂系统的重要一次设备。它具有噪音低,使用寿命长,操作频繁等优点。主要用于工厂高压电机的控制。如果反复开断开关,会对电机的定子线圈和转子鼠笼棒产生很大的冲击力,损坏绕组的绝缘,造成鼠笼棒过热断裂。同时,还可能造成母线接地,开关触点损坏甚至爆炸。因此,有必要对电厂高压真空接触器防跳控制回路故障原因进行分析探讨,寻求解决“防跳”方案。通过分析优化控制回路,解决故障,并对6kV真空开关和光纤开关的防跳电路提供技术支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信