Control of Minimum-Heat-Flux-Point Temperature by the Thermal Conductance of an Additional Surface-Layer : Series B : Fluid Engineering, Heat Transfer, Combustion, Power, Thermophysical Properties
{"title":"Control of Minimum-Heat-Flux-Point Temperature by the Thermal Conductance of an Additional Surface-Layer : Series B : Fluid Engineering, Heat Transfer, Combustion, Power, Thermophysical Properties","authors":"S. Nishio, Yoshihiro Serizawa","doi":"10.1299/KIKAIB.53.1061","DOIUrl":null,"url":null,"abstract":"In the present paper, the effects of thermal conductance of a boiling surface on the minimum-heat-flux-point temperature and film-boiling heat transfer of saturated pool boiling of liquid nitrogen on a horizontal flat-surface of copper are experimentally studied. The thermal conductance of the copper surface was changed by the following two additional-layers coated on it. The first is a thin layer of low thermal-conductivity material coated on the copper surface. The second is a additional double-layer that consists of a 0.3 mm PTFE layer and a thin metallic layer coated on it. The experimental results show that the effects of such additional layers on film boiling are negligible but are remarkable on the MHF-point temperature. For the single insulating layers, the MHF-point temperature increases with increased coating thicknesses. As for the additional double-layers, the MHF-point temperature decreses rapidly with increased thicknesses of the outer layer. In both cases, the MHF-point temperature reaches (or comes back to) a unique value when the coating material has a coating thickness of 0.1∼1 mm.","PeriodicalId":286527,"journal":{"name":"JSME international journal : bulletin of the JSME","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSME international journal : bulletin of the JSME","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/KIKAIB.53.1061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
In the present paper, the effects of thermal conductance of a boiling surface on the minimum-heat-flux-point temperature and film-boiling heat transfer of saturated pool boiling of liquid nitrogen on a horizontal flat-surface of copper are experimentally studied. The thermal conductance of the copper surface was changed by the following two additional-layers coated on it. The first is a thin layer of low thermal-conductivity material coated on the copper surface. The second is a additional double-layer that consists of a 0.3 mm PTFE layer and a thin metallic layer coated on it. The experimental results show that the effects of such additional layers on film boiling are negligible but are remarkable on the MHF-point temperature. For the single insulating layers, the MHF-point temperature increases with increased coating thicknesses. As for the additional double-layers, the MHF-point temperature decreses rapidly with increased thicknesses of the outer layer. In both cases, the MHF-point temperature reaches (or comes back to) a unique value when the coating material has a coating thickness of 0.1∼1 mm.