Testing of the accuracy dependency of prismless distance measurement on the beam incidence angle

Pavel Třasák, M. Štroner, V. Smítka, R. Urban
{"title":"Testing of the accuracy dependency of prismless distance measurement on the beam incidence angle","authors":"Pavel Třasák, M. Štroner, V. Smítka, R. Urban","doi":"10.14311/GI.7.10","DOIUrl":null,"url":null,"abstract":"The article assesses the precision development of distance measurement using prismless distance meters, both in relation to the changing length of the measured distance and the changing incidence angle of the distance meter’s beam. The article presents the design and performance of an original experiment, the characteristics of instruments used, statistical evaluation of experimental data and formulation of conclusions on the precision rate of distance measurement using prismless instruments.","PeriodicalId":436054,"journal":{"name":"Geoinformatics FCE CTU","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geoinformatics FCE CTU","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14311/GI.7.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The article assesses the precision development of distance measurement using prismless distance meters, both in relation to the changing length of the measured distance and the changing incidence angle of the distance meter’s beam. The article presents the design and performance of an original experiment, the characteristics of instruments used, statistical evaluation of experimental data and formulation of conclusions on the precision rate of distance measurement using prismless instruments.
无棱镜距离测量精度对光束入射角依赖性的检验
本文从测量距离长度的变化和测距仪光束入射角的变化两方面对无棱镜测距仪测量距离的精度发展进行了评价。本文介绍了一个原始实验的设计和性能,所使用的仪器的特点,实验数据的统计评价,以及用无棱镜仪器测量距离的精度率的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信