{"title":"Estimation of Chest Compression Rate and Detection of Hands-off Intervals During Resuscitation With Automated External Defibrillators","authors":"J. Ruiz, S. R. D. Gauna, P. Bahillo, D. González-Otero, P. Sáiz, Daniel Alonso, Karlos Ibarguren","doi":"10.22489/CinC.2018.246","DOIUrl":null,"url":null,"abstract":"Quality of chest compressions (CCs) is key for patient's survival to cardiac arrest. Incorporating real-time feedback on CC rate in automated external defibrillators (AEDs) could enhance CC quality. The aim of the study was to design a method for detecting CC pauses and computing CC rate using the transthoracic impedance (TI) signal acquired from the AED defibrillation pads. We collected 35 AED recordings from a database property of Emergentziak-Osakidetza (Basque Country, Spain). Using the ECG and TI signals, a CC pause was annotated when CCs were interrupted for more than 3 s. The algorithm estimates the CC rate from the autocorrelation of 2-s consecutive TI intervals. The algorithm reported a sensitivity (Se) and a positive predictive value (PPV) in the detection of CC pauses of 97.64%/92.48%. Reliable CC rates were obtained with a Se/PPV of 99.03%/98.61%. Unreliable CC rates were reported only in 0.9% of the cases. A method based on the autocorrelation of the TI signal allows reliable detection of CC pauses and estimation of CC rates, enhancing current AED functionality.","PeriodicalId":215521,"journal":{"name":"2018 Computing in Cardiology Conference (CinC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Computing in Cardiology Conference (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2018.246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Quality of chest compressions (CCs) is key for patient's survival to cardiac arrest. Incorporating real-time feedback on CC rate in automated external defibrillators (AEDs) could enhance CC quality. The aim of the study was to design a method for detecting CC pauses and computing CC rate using the transthoracic impedance (TI) signal acquired from the AED defibrillation pads. We collected 35 AED recordings from a database property of Emergentziak-Osakidetza (Basque Country, Spain). Using the ECG and TI signals, a CC pause was annotated when CCs were interrupted for more than 3 s. The algorithm estimates the CC rate from the autocorrelation of 2-s consecutive TI intervals. The algorithm reported a sensitivity (Se) and a positive predictive value (PPV) in the detection of CC pauses of 97.64%/92.48%. Reliable CC rates were obtained with a Se/PPV of 99.03%/98.61%. Unreliable CC rates were reported only in 0.9% of the cases. A method based on the autocorrelation of the TI signal allows reliable detection of CC pauses and estimation of CC rates, enhancing current AED functionality.