An Investigation on the Influence of Blood Volume in the Cardiac Cycle on Channel Gain of Intracardiac Communication Channels

Yiming Liu, Yueming Gao, Liting Chen, Z. Chen, S. Pun, M. Vai
{"title":"An Investigation on the Influence of Blood Volume in the Cardiac Cycle on Channel Gain of Intracardiac Communication Channels","authors":"Yiming Liu, Yueming Gao, Liting Chen, Z. Chen, S. Pun, M. Vai","doi":"10.1109/imbioc52515.2022.9790211","DOIUrl":null,"url":null,"abstract":"In galvanic coupling conductive intracardiac communication(GCCIC) of the leadless pacemaker, the electrical signal transmitted directly through the myocardium and blood is inevitably affected by the cardiac cycle. The existed research paid more attention to the effect of the myocardium during communication. However, experiments show the change of blood volume also has a great impact on signal transmission. In this paper, the cardiac cycle is divided into seven phases with different blood volumes periodically, and the signal gain is monitored through a homemade dynamic measurement platform with two peristaltic pumps and several silicone tubes. Through in vitro experiment of the porcine heart, the changes of two channel gains caused by the cardiac cycle are analyzed. The results show that channel gains change periodically with the change of blood volume in the cardiac cycle, and the change trends of the two channels are different because the signal paths in the two channels are different. For the Right Ventricle - Right Atrium channel, gain varies from −62 to −47 dB and channel gain is inversely correlated with blood volume. For the Right Ventricle - Left Ventricle channel, when blood volume is less than 80 mL, channel gain is about −51 dB. And when blood volume is greater than 80 mL, channel gain fluctuates around −48 dB. This study shows the gain of the intracardiac communication channel is affected by the change of blood volume in the cardiac cycle.","PeriodicalId":305829,"journal":{"name":"2022 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","volume":"23 11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/imbioc52515.2022.9790211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In galvanic coupling conductive intracardiac communication(GCCIC) of the leadless pacemaker, the electrical signal transmitted directly through the myocardium and blood is inevitably affected by the cardiac cycle. The existed research paid more attention to the effect of the myocardium during communication. However, experiments show the change of blood volume also has a great impact on signal transmission. In this paper, the cardiac cycle is divided into seven phases with different blood volumes periodically, and the signal gain is monitored through a homemade dynamic measurement platform with two peristaltic pumps and several silicone tubes. Through in vitro experiment of the porcine heart, the changes of two channel gains caused by the cardiac cycle are analyzed. The results show that channel gains change periodically with the change of blood volume in the cardiac cycle, and the change trends of the two channels are different because the signal paths in the two channels are different. For the Right Ventricle - Right Atrium channel, gain varies from −62 to −47 dB and channel gain is inversely correlated with blood volume. For the Right Ventricle - Left Ventricle channel, when blood volume is less than 80 mL, channel gain is about −51 dB. And when blood volume is greater than 80 mL, channel gain fluctuates around −48 dB. This study shows the gain of the intracardiac communication channel is affected by the change of blood volume in the cardiac cycle.
心周期血容量对心内通信通道增益影响的研究
在无导线起搏器的电偶联传导心内通信(GCCIC)中,直接通过心肌和血液传递的电信号不可避免地受到心动周期的影响。现有的研究多关注心肌在传递过程中的作用。然而,实验表明,血容量的变化对信号传输也有很大的影响。本文将心脏周期周期性地分为7个不同血容量的阶段,并通过自制的由两个蠕动泵和几个硅胶管组成的动态测量平台监测信号增益。通过猪心脏体外实验,分析了心脏周期对两通道增益的影响。结果表明,通道增益随心周期血容量的变化而周期性变化,且由于两个通道中的信号路径不同,通道增益的变化趋势不同。对于右心室-右心房通道,增益从- 62到- 47 dB不等,通道增益与血容量呈负相关。对于右心室-左心室通道,当血容量小于80 mL时,通道增益约为- 51 dB。当血容量大于80 mL时,通道增益在−48 dB左右波动。本研究表明心内通信通道的增益受心周期血容量变化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信