A review of high-impedance and low-impedance differential relaying for bus protection

S. Pavavicharn, G. Johnson
{"title":"A review of high-impedance and low-impedance differential relaying for bus protection","authors":"S. Pavavicharn, G. Johnson","doi":"10.1109/CPRE.2014.6799038","DOIUrl":null,"url":null,"abstract":"Differential protection is usually applied on bus protection because of its high selectivity since it does not need to coordinate with other relays. Bus differential protection in power system networks operates on a principle defined by Kirchoff's current law. The law states that the vector sum of all currents entering and leaving a node or bus is equal to zero. It is this principle that is used in all bus differential protection regardless of the relay type used. This paper discusses the fundamentals of bus protection with a focus on the two common methods typically used: high-impedance and low-impedance bus differential relaying. Included are the basic theories of high impedance and low-impedance differential relaying and their operational concepts. A comparison between the two methods which points out the benefits, drawbacks, concerns and considerations is also given. The importance of current transformer selection and performance are considered in this paper as part of the consideration in bus differential protection scheme design.","PeriodicalId":285252,"journal":{"name":"2014 67th Annual Conference for Protective Relay Engineers","volume":"442 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 67th Annual Conference for Protective Relay Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2014.6799038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Differential protection is usually applied on bus protection because of its high selectivity since it does not need to coordinate with other relays. Bus differential protection in power system networks operates on a principle defined by Kirchoff's current law. The law states that the vector sum of all currents entering and leaving a node or bus is equal to zero. It is this principle that is used in all bus differential protection regardless of the relay type used. This paper discusses the fundamentals of bus protection with a focus on the two common methods typically used: high-impedance and low-impedance bus differential relaying. Included are the basic theories of high impedance and low-impedance differential relaying and their operational concepts. A comparison between the two methods which points out the benefits, drawbacks, concerns and considerations is also given. The importance of current transformer selection and performance are considered in this paper as part of the consideration in bus differential protection scheme design.
母线保护用高阻抗和低阻抗差分继电保护综述
差动保护不需要与其他继电器配合,具有较高的选择性,通常应用于母线保护。电力系统网络中的母线差动保护工作原理由基尔霍夫电流定律定义。该定律指出,进入和离开节点或总线的所有电流的矢量和等于零。无论采用何种继电器类型,所有母线差动保护都采用这一原理。本文讨论了母线保护的基本原理,重点介绍了两种常用的方法:高阻抗和低阻抗母线差分继电器。介绍了高阻抗和低阻抗差动继电器的基本原理及其操作概念。并对两种方法进行了比较,指出了两种方法的优点、缺点和需要注意的问题。在母线差动保护方案设计中,电流互感器的选择和性能是考虑因素的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信