Methodological aspects of optimization of energy consump-tion costs of low-rise buildings with a built-in air heat pump

E. Krupnov, I. A. Zaitseva, S. Loginova, I. S. Zaitsev
{"title":"Methodological aspects of optimization of energy consump-tion costs of low-rise buildings with a built-in air heat pump","authors":"E. Krupnov, I. A. Zaitseva, S. Loginova, I. S. Zaitsev","doi":"10.21822/2073-6185-2023-50-2-177-187","DOIUrl":null,"url":null,"abstract":"Objective. The rational use of fuel and energy resources is one of the urgent problems. One of the promising ways to solve this problem is the use of environmentally friendly energy-saving air source heat pumps based on the use of non-traditional energy sources. The use of such innovative energy-saving technologies requires not only modern architectural and planning, design and engineering solutions, but also sound methodological recommendations for as-sessing their energy efficiency and feasibility. The article presents a methodology for calculating the consumed electrical energy and heat generation, as well as the seasonal indicator of energy efficiency in the operation of an air source heat pump.Method. The technique takes into account, as input data, experimental data from tests of high-voltage heat pumps in terms of heat output depending on the change in the temperature of the source of low-grade heat and the temperature regime of the coolant.Result. The need to develop a methodology is due to the shortcomings in the regulatory documents of the methodological basis for optimizing energy costs and heat generation by heat pumps. The accuracy of calculating the operating costs that will occur during the heating period of the air source heat pump (AHP) depends on the correct accounting of the required heat load of a low-rise building and the consumption of electricity to ensure it.Conclusion. This technique can be applied not only to calculate the annual operating costs of using a heat pump and determine the structure of energy consumption (thermal and electrical), but also to optimize the energy parameters of HHP with an assessment of the energy efficiency of different options for their configurations.","PeriodicalId":202454,"journal":{"name":"Herald of Dagestan State Technical University. Technical Sciences","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Herald of Dagestan State Technical University. Technical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21822/2073-6185-2023-50-2-177-187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective. The rational use of fuel and energy resources is one of the urgent problems. One of the promising ways to solve this problem is the use of environmentally friendly energy-saving air source heat pumps based on the use of non-traditional energy sources. The use of such innovative energy-saving technologies requires not only modern architectural and planning, design and engineering solutions, but also sound methodological recommendations for as-sessing their energy efficiency and feasibility. The article presents a methodology for calculating the consumed electrical energy and heat generation, as well as the seasonal indicator of energy efficiency in the operation of an air source heat pump.Method. The technique takes into account, as input data, experimental data from tests of high-voltage heat pumps in terms of heat output depending on the change in the temperature of the source of low-grade heat and the temperature regime of the coolant.Result. The need to develop a methodology is due to the shortcomings in the regulatory documents of the methodological basis for optimizing energy costs and heat generation by heat pumps. The accuracy of calculating the operating costs that will occur during the heating period of the air source heat pump (AHP) depends on the correct accounting of the required heat load of a low-rise building and the consumption of electricity to ensure it.Conclusion. This technique can be applied not only to calculate the annual operating costs of using a heat pump and determine the structure of energy consumption (thermal and electrical), but also to optimize the energy parameters of HHP with an assessment of the energy efficiency of different options for their configurations.
采用内置空气热泵的低层建筑能耗成本优化的方法学方面
目标。合理利用燃料和能源是亟待解决的问题之一。解决这一问题的一种很有前景的方法是在使用非传统能源的基础上使用环保节能的空气源热泵。使用这种创新的节能技术不仅需要现代的建筑和规划、设计和工程解决方案,而且还需要评估其能源效率和可行性的合理方法建议。本文提出了一种计算空气源热泵运行中消耗的电能和产生的热量的方法,以及能效的季节性指标。该技术考虑了作为输入数据的高压热泵测试的实验数据,根据低品位热源的温度变化和冷却剂的温度状态的热输出。开发一种方法的需要是由于优化能源成本和热泵产生热量的方法基础的规范性文件中的缺点。空气源热泵(AHP)采暖期间运行成本计算的准确性取决于对低层建筑所需热负荷和用电量的正确核算,以保证其准确性。该技术不仅可以用于计算使用热泵的年运行成本,确定能耗结构(热、电),还可以通过评估不同配置方案的能效来优化HHP的能量参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信