{"title":"Low cost rangemap obtaining for mobile robots based on a triangulation rangefinder","authors":"H. Lamela, J.R. Lopez, E. García","doi":"10.1109/IECON.1997.668497","DOIUrl":null,"url":null,"abstract":"The objective of the present work is the development of a low-cost triangulation rangefinder, capable of providing a cost effective alternative to ultrasonic rangefinders with the superior performance of optical systems. On one hand, light is not reflected, but backscattered by man-made surfaces, thus eliminating the problem of multipath echoes. On the other hand, the divergence of a light beam is much smaller than that of an ultrasonic beam, which allows for higher lateral resolution. In this paper, we show first the measuring technique and the system developed in this work. And then we show the results achieved with this system.","PeriodicalId":404447,"journal":{"name":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1997.668497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The objective of the present work is the development of a low-cost triangulation rangefinder, capable of providing a cost effective alternative to ultrasonic rangefinders with the superior performance of optical systems. On one hand, light is not reflected, but backscattered by man-made surfaces, thus eliminating the problem of multipath echoes. On the other hand, the divergence of a light beam is much smaller than that of an ultrasonic beam, which allows for higher lateral resolution. In this paper, we show first the measuring technique and the system developed in this work. And then we show the results achieved with this system.
基于三角测距仪的移动机器人低成本测距图获取
本文的目标是开发一种低成本的三角测距仪,能够提供一种具有光学系统优越性能的超声测距仪的经济有效的替代品。一方面,光不会被反射,而是被人造表面反向散射,从而消除了多径回波的问题。另一方面,光束的发散比超声波光束的发散要小得多,这允许更高的横向分辨率。本文首先介绍了这项工作所开发的测量技术和系统。然后我们展示了用这个系统取得的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信