Experiences from over 15 years of on-line partial discharge (OLPD) testing of in-service MV and HV cables, switchgear, transformers and rotating machines
L. Renforth, M. Seltzer-Grant, R. Mackinlay, S. Goodfellow, D. Clark, R. Shuttleworth
{"title":"Experiences from over 15 years of on-line partial discharge (OLPD) testing of in-service MV and HV cables, switchgear, transformers and rotating machines","authors":"L. Renforth, M. Seltzer-Grant, R. Mackinlay, S. Goodfellow, D. Clark, R. Shuttleworth","doi":"10.1109/LARC.2011.6086862","DOIUrl":null,"url":null,"abstract":"The authors present a paper on the application of online partial discharge (PD) testing and monitoring technology for the insulation condition assessment of in service medium voltage (MV — 3.3kV to 45kV)) and high voltage (HV — 66kV to 750kV) cables and plant. The paper begins with a short summary of the different economic ‘DRIVERS’ which apply to both public utility and industrial HV networks. The paper presents some of the test techniques employed and the on-line PD sensor technology used to test in-service power cables, switchgear, transformers, rotating machines, CTs/VTs and other HV plant. The paper concludes with some case studies of past projects carried out by the authors from on-line PD test projects testing a wide range of MV & HV assets in electricity networks around the world.","PeriodicalId":419849,"journal":{"name":"IX Latin American Robotics Symposium and IEEE Colombian Conference on Automatic Control, 2011 IEEE","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IX Latin American Robotics Symposium and IEEE Colombian Conference on Automatic Control, 2011 IEEE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LARC.2011.6086862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
The authors present a paper on the application of online partial discharge (PD) testing and monitoring technology for the insulation condition assessment of in service medium voltage (MV — 3.3kV to 45kV)) and high voltage (HV — 66kV to 750kV) cables and plant. The paper begins with a short summary of the different economic ‘DRIVERS’ which apply to both public utility and industrial HV networks. The paper presents some of the test techniques employed and the on-line PD sensor technology used to test in-service power cables, switchgear, transformers, rotating machines, CTs/VTs and other HV plant. The paper concludes with some case studies of past projects carried out by the authors from on-line PD test projects testing a wide range of MV & HV assets in electricity networks around the world.