Bode Stability Criterion Pertaining to SSR Analysis for Second Benchmark Model in DFIG Based Windfarm

Chirag Rohit, Azadkumar G. Bolabattin, P. Darji, H. Jariwala
{"title":"Bode Stability Criterion Pertaining to SSR Analysis for Second Benchmark Model in DFIG Based Windfarm","authors":"Chirag Rohit, Azadkumar G. Bolabattin, P. Darji, H. Jariwala","doi":"10.1109/NPSC57038.2022.10069059","DOIUrl":null,"url":null,"abstract":"This paper presents impedance-based Bode stability analysis to investigate and mitigate the sub-synchronous resonance (SSR) of doubly-fed induction generator (DFIG)based series compensated network. A transmission line model is adapted from the IEEE Second Benchmark Model. The study system is developed by the impedance modeling of DFIG and network model. The Bode stability study of series compensated transmission lines is carried out at various compensation levels and wind speeds. Based on the stability analysis performed on the system, the system is unstable at high compensation levels of transmission lines and low wind speeds. Hence to mitigate SSR, an approximate damping gain is derived from the stability margins acquired in the Bode plot. The results indicate that the approach for calculating approximate damping gain provided in this study successfully dampens SSR under critical conditions.","PeriodicalId":162808,"journal":{"name":"2022 22nd National Power Systems Conference (NPSC)","volume":"34 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 22nd National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC57038.2022.10069059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents impedance-based Bode stability analysis to investigate and mitigate the sub-synchronous resonance (SSR) of doubly-fed induction generator (DFIG)based series compensated network. A transmission line model is adapted from the IEEE Second Benchmark Model. The study system is developed by the impedance modeling of DFIG and network model. The Bode stability study of series compensated transmission lines is carried out at various compensation levels and wind speeds. Based on the stability analysis performed on the system, the system is unstable at high compensation levels of transmission lines and low wind speeds. Hence to mitigate SSR, an approximate damping gain is derived from the stability margins acquired in the Bode plot. The results indicate that the approach for calculating approximate damping gain provided in this study successfully dampens SSR under critical conditions.
基于DFIG的风电场二次基准模型SSR分析的Bode稳定性准则
本文提出了基于阻抗的波德稳定性分析方法来研究和缓解双馈感应发电机串联补偿网络的次同步谐振。传输线模型改编自IEEE第二基准模型。研究系统采用DFIG的阻抗建模和网络模型。对串联补偿输电线路在不同补偿水平和风速下的波德稳定性进行了研究。通过对系统的稳定性分析可知,在输电线路高补偿水平和低风速条件下,系统是不稳定的。因此,为了减轻SSR,从波德图中获得的稳定裕度推导出近似的阻尼增益。结果表明,本文提供的近似阻尼增益计算方法成功地抑制了临界条件下的SSR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信