Influence of Different Reline Materials and Processing Methods on Flexural Strength of Denture Base Material

O. Oflezer, H. Bahadır, Senem Ünver, C. Oflezer
{"title":"Influence of Different Reline Materials and Processing Methods on Flexural Strength of Denture Base Material","authors":"O. Oflezer, H. Bahadır, Senem Ünver, C. Oflezer","doi":"10.2478/bjdm-2021-0017","DOIUrl":null,"url":null,"abstract":"Summary Background/Aim: Relining is defined as the procedure used to resurface the tissue side of a denture with new base material, thus producing an accurate adaptation is provided at the denture foundation area. During mastication, relined dentures have to withstand masticatory forces to prevent fracture. The aim of this study was to evaluate the flexural strength of acrylic resin denture base relined with different methods and materials. Material and Methods: Fourteen experimental groups and one control group were determined to consider different reline materials and processing methods. Acrylic resin specimens were prepared with the dimensions of 65× 10× 1.5 mm and reline materials (1.5 mm thickness) were placed on acrylic resins. Reline material was not used in control group specimens. Flexural strength values of relined and control specimens were measured with three-point bending test at a speed of 5 mm/min. Data were analyzed with using one way Anova and Student t tests. Results: The highest flexural strength values were shown in control group (86.51±1.08 MPa). There were significant differences among relined specimens (p< 0.05). For the relined specimens, the highest flexural strength values were found in the relined specimens with denture base material (77.90±1.93 MPa), and the lowest values were found in relined with autopolymerize acrylic material (59.81±1.50 MPa). Conclusions: Relining of the heat cure denture base material significantly decreases the flexural strength for all processing methods and materials.","PeriodicalId":161469,"journal":{"name":"Balkan Journal of Dental Medicine","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Balkan Journal of Dental Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/bjdm-2021-0017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Summary Background/Aim: Relining is defined as the procedure used to resurface the tissue side of a denture with new base material, thus producing an accurate adaptation is provided at the denture foundation area. During mastication, relined dentures have to withstand masticatory forces to prevent fracture. The aim of this study was to evaluate the flexural strength of acrylic resin denture base relined with different methods and materials. Material and Methods: Fourteen experimental groups and one control group were determined to consider different reline materials and processing methods. Acrylic resin specimens were prepared with the dimensions of 65× 10× 1.5 mm and reline materials (1.5 mm thickness) were placed on acrylic resins. Reline material was not used in control group specimens. Flexural strength values of relined and control specimens were measured with three-point bending test at a speed of 5 mm/min. Data were analyzed with using one way Anova and Student t tests. Results: The highest flexural strength values were shown in control group (86.51±1.08 MPa). There were significant differences among relined specimens (p< 0.05). For the relined specimens, the highest flexural strength values were found in the relined specimens with denture base material (77.90±1.93 MPa), and the lowest values were found in relined with autopolymerize acrylic material (59.81±1.50 MPa). Conclusions: Relining of the heat cure denture base material significantly decreases the flexural strength for all processing methods and materials.
不同线材及加工方法对义齿基托材料抗弯强度的影响
背景/目的:重衬是指用新的基托材料重新表面义齿的组织面,从而在义齿基托区域产生准确的适应。在咀嚼过程中,有衬义齿必须承受咀嚼力以防止骨折。本研究的目的是评估不同方法和材料的丙烯酸树脂义齿基托的抗弯强度。材料与方法:选择14个实验组和1个对照组,分别考虑不同的线材和加工方法。制作尺寸为65× 10× 1.5 mm的丙烯酸树脂样品,并在丙烯酸树脂上放置1.5 mm厚度的线材。对照组标本不采用线状材料。采用三点弯曲试验,以5 mm/min的速度测量线材和对照试件的抗弯强度值。数据分析采用单因素方差分析和学生t检验。结果:对照组的抗折强度值最高(86.51±1.08 MPa)。有线标本间差异有统计学意义(p< 0.05)。用义齿基托材料加固的试件抗弯强度值最高(77.90±1.93 MPa),用自聚合丙烯酸树脂加固的试件抗弯强度值最低(59.81±1.50 MPa)。结论:热固化义齿基托材料的复衬明显降低了所有加工方法和材料的抗弯强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信