{"title":"LFC Investigation with SHO tuned 1 Plus Fraction ID Controller","authors":"J. Padhi, M. Debnath, S. Kar","doi":"10.1109/ODICON50556.2021.9429008","DOIUrl":null,"url":null,"abstract":"LFC (Load Frequency Control) in power system is essential to normalize the frequency deviations in power system during unpredicted load perturbations. Novel 1 Plus Fraction ID (1 plus FID) Controller is recommended in this article to adjust the frequency fluctuations in a dual area thermal system with EV aggregators. The gains of projected 1 plus FID controllers are carefully chosen by Selfish Herd Optimization (SHO) in the presence of an abrupt disturbance of 10% in control area 1 utilizing integral time absolute error (ITAE) as the objective/fitness function. In the initial analysis the dominance of 1 plus FID controller is witnessed over the PID controller during 10% load deviation in control area 1. In the latter case the effectiveness of the projected 1 plus FID controller is certified by applying haphazard loading in control area 1. The examination of the system responses are presented to establish the ascendency of the projected SHO tuned 1 plus FID controller over existing PID controller on the basis of settling time, undershoots and overshoots.","PeriodicalId":197132,"journal":{"name":"2021 1st Odisha International Conference on Electrical Power Engineering, Communication and Computing Technology(ODICON)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 1st Odisha International Conference on Electrical Power Engineering, Communication and Computing Technology(ODICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ODICON50556.2021.9429008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
LFC (Load Frequency Control) in power system is essential to normalize the frequency deviations in power system during unpredicted load perturbations. Novel 1 Plus Fraction ID (1 plus FID) Controller is recommended in this article to adjust the frequency fluctuations in a dual area thermal system with EV aggregators. The gains of projected 1 plus FID controllers are carefully chosen by Selfish Herd Optimization (SHO) in the presence of an abrupt disturbance of 10% in control area 1 utilizing integral time absolute error (ITAE) as the objective/fitness function. In the initial analysis the dominance of 1 plus FID controller is witnessed over the PID controller during 10% load deviation in control area 1. In the latter case the effectiveness of the projected 1 plus FID controller is certified by applying haphazard loading in control area 1. The examination of the system responses are presented to establish the ascendency of the projected SHO tuned 1 plus FID controller over existing PID controller on the basis of settling time, undershoots and overshoots.