Pneumatic Sleeve-Assisted Stable sEMG Measurement for Microneedle Array Electrode

Minjae Kim, Gangyong Gu, Woongyong Lee, W. Chung
{"title":"Pneumatic Sleeve-Assisted Stable sEMG Measurement for Microneedle Array Electrode","authors":"Minjae Kim, Gangyong Gu, Woongyong Lee, W. Chung","doi":"10.1109/URAI.2018.8441867","DOIUrl":null,"url":null,"abstract":"Surface electromyography (sEMG) signals contain information about a users intention. With this in mind, several types of sEMG electrodes have been proposed to reliably measure sEMG signals. Microneedle array (MNA) electrodes have been proposed to measure low skin impedance sEMG signals without any additional medium. However, the MNA electrode is vulnerable to motion owing to its small skin contact area. Therefore, the sEMG signal measured by the MNA electrode significantly depends on the skin contact condition. This paper proposes pneumatic sleeve-assisted microneedle-based sEMG signal measurement. The pneumatic sleeve provides stable skin contact during dynamic motions by using compressed air to secure the electrodes. The performance of the pneumatic sleeve-assisted sEMG signal measurement was compared with that of Velcro band-based sEMG signal measurement to demonstrate the usefulness of the pneumatic sleeve for sEMG signal measurement.","PeriodicalId":347727,"journal":{"name":"2018 15th International Conference on Ubiquitous Robots (UR)","volume":"139 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 15th International Conference on Ubiquitous Robots (UR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/URAI.2018.8441867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Surface electromyography (sEMG) signals contain information about a users intention. With this in mind, several types of sEMG electrodes have been proposed to reliably measure sEMG signals. Microneedle array (MNA) electrodes have been proposed to measure low skin impedance sEMG signals without any additional medium. However, the MNA electrode is vulnerable to motion owing to its small skin contact area. Therefore, the sEMG signal measured by the MNA electrode significantly depends on the skin contact condition. This paper proposes pneumatic sleeve-assisted microneedle-based sEMG signal measurement. The pneumatic sleeve provides stable skin contact during dynamic motions by using compressed air to secure the electrodes. The performance of the pneumatic sleeve-assisted sEMG signal measurement was compared with that of Velcro band-based sEMG signal measurement to demonstrate the usefulness of the pneumatic sleeve for sEMG signal measurement.
微针阵列电极气动套筒辅助稳定表面肌电信号测量
表面肌电图(sEMG)信号包含有关用户意图的信息。考虑到这一点,已经提出了几种类型的表面肌电信号电极来可靠地测量表面肌电信号。微针阵列(MNA)电极已经被提出用于测量低皮肤阻抗的表面肌电信号,而不需要任何额外的介质。然而,由于其皮肤接触面积小,MNA电极容易受到运动的影响。因此,MNA电极测量的表面肌电信号明显依赖于皮肤接触条件。提出了一种基于气动套筒辅助微针的表面肌电信号测量方法。气动套筒通过使用压缩空气来固定电极,在动态运动中提供稳定的皮肤接触。将气动套筒辅助表面肌电信号测量的性能与基于魔术贴的表面肌电信号测量的性能进行了比较,以证明气动套筒辅助表面肌电信号测量的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信