Fundamental Studies on Tissue Reaction after Low Power Laser Irradiation

A. Shinohara, Mugio Kato, T. Imai, Kenji Yoshida, S. Yamada, K. Kurita
{"title":"Fundamental Studies on Tissue Reaction after Low Power Laser Irradiation","authors":"A. Shinohara, Mugio Kato, T. Imai, Kenji Yoshida, S. Yamada, K. Kurita","doi":"10.5984/JJPNSOCLASERDENT.9.38","DOIUrl":null,"url":null,"abstract":"It is generally recognized that the lower power Nd: YAG laser provides some therapeutic effects on tissue without irreversible changes. On the other hand, high power laser causes irreversible changes. The criterion about low and high power laser is, however, not established. The aim of this study is to verify the effect of lower and high power laser on wound healing of rat skin by measuring blood flow and histomorphologic findings with HE and SEM. Each laser were irradiated to the center of 6mm round full-thickness skin defect at the back of the rat at either (1) 300mW×3min, (2) 500mW×3min, (3) 700mW×3min, (4) 300mW×20min, (5) 500mw×20min, (6) 700mW×20min.The results obtained are as follows;1) The histological findings showed that irradiation time caused more tissue damage in the deeper layer, whereas irradiation power caused more damage to the surrounding tissue.2) Small craters were starred on the bottom of the damaged tissue by laser irradiation at 700 mW x 20min. The formation of these craters was related to the absorption of laser irradiation.3) On the irradiated area, blood volume decreased significantly as irradiation power increased. However, both blood flow and tissue damage increased as irradiation time increased. As for the surrounding tissue, the findings showed an increase in the blood flow and tissue damage as irra diation power increased.4) High power laser at 700mW caused tissue damage regardless of irradiation time. On the other hand, 500mW irradiation power caused minimum damage to the tissue. Therefore, the range between 300 to 500mW and the irraditation time over 3min to less than 20min are classified as a lower power laser.","PeriodicalId":187459,"journal":{"name":"Journal of Japanese Society for Laser Dentistry","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Japanese Society for Laser Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5984/JJPNSOCLASERDENT.9.38","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It is generally recognized that the lower power Nd: YAG laser provides some therapeutic effects on tissue without irreversible changes. On the other hand, high power laser causes irreversible changes. The criterion about low and high power laser is, however, not established. The aim of this study is to verify the effect of lower and high power laser on wound healing of rat skin by measuring blood flow and histomorphologic findings with HE and SEM. Each laser were irradiated to the center of 6mm round full-thickness skin defect at the back of the rat at either (1) 300mW×3min, (2) 500mW×3min, (3) 700mW×3min, (4) 300mW×20min, (5) 500mw×20min, (6) 700mW×20min.The results obtained are as follows;1) The histological findings showed that irradiation time caused more tissue damage in the deeper layer, whereas irradiation power caused more damage to the surrounding tissue.2) Small craters were starred on the bottom of the damaged tissue by laser irradiation at 700 mW x 20min. The formation of these craters was related to the absorption of laser irradiation.3) On the irradiated area, blood volume decreased significantly as irradiation power increased. However, both blood flow and tissue damage increased as irradiation time increased. As for the surrounding tissue, the findings showed an increase in the blood flow and tissue damage as irra diation power increased.4) High power laser at 700mW caused tissue damage regardless of irradiation time. On the other hand, 500mW irradiation power caused minimum damage to the tissue. Therefore, the range between 300 to 500mW and the irraditation time over 3min to less than 20min are classified as a lower power laser.
低功率激光辐照后组织反应的基础研究
人们普遍认为,低功率Nd: YAG激光对组织有一定的治疗作用,但没有不可逆的变化。另一方面,高功率激光会引起不可逆的变化。然而,关于低功率和高功率激光的标准还没有建立起来。本研究的目的是通过HE和SEM测量血流和组织形态学结果,验证低功率和高功率激光对大鼠皮肤伤口愈合的影响。在(1)300mW×3min, (2) 500mW×3min, (3) 700mW×3min, (4) 300mW×20min, (5) 500mw×20min, (6) 700mW×20min处,每束激光照射大鼠背部6mm圆形全层皮肤缺损中心。结果表明:1)组织学结果显示,照射时间对深层组织损伤更大,而照射功率对周围组织损伤更大。2)激光照射700 mW x 20min后,损伤组织底部形成小凹坑。这些凹坑的形成与激光照射的吸收有关。3)在照射区域,随着照射功率的增加,血容量明显减少。然而,随着照射时间的延长,血流量和组织损伤均增加。对于周围组织,随着照射功率的增加,血流量增加,组织损伤增加。4)无论照射时间如何,700mW高功率激光均引起组织损伤。另一方面,500mW的辐照功率对组织的损伤最小。因此,在300 ~ 500mW之间,照射时间大于3min ~小于20min的激光器被归类为低功率激光器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信