D. Tugay, S. Korneliuk, Valentyn Akymov, G. Zhemerov
{"title":"Localization of the Phase Voltage Measurement Location for Active Power Filter Controlling","authors":"D. Tugay, S. Korneliuk, Valentyn Akymov, G. Zhemerov","doi":"10.1109/IEPS51250.2020.9263137","DOIUrl":null,"url":null,"abstract":"The quality of compensation of harmonic distortions for network voltages and currents by means of the power active filter depends on the control system settings. The difference in quality indicators of power supply when placing phase sensors of the network to generate a reference signal for two possible cases – on the network terminals and on the load terminals (at the point of load connection) is showed in the paper. It is proved that in asymmetrical modes of three-phase power supply system operation the placement of phase voltage sensors on load terminals leads to a decrease in the efficiency, shift coefficient and an increase in the THD of a network phase voltages and currents in comparison with the second case. The developed theoretical propositions using the modeling of power supply system with power active filter in Matlab environment are confirmed.","PeriodicalId":235261,"journal":{"name":"2020 IEEE 4th International Conference on Intelligent Energy and Power Systems (IEPS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 4th International Conference on Intelligent Energy and Power Systems (IEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEPS51250.2020.9263137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The quality of compensation of harmonic distortions for network voltages and currents by means of the power active filter depends on the control system settings. The difference in quality indicators of power supply when placing phase sensors of the network to generate a reference signal for two possible cases – on the network terminals and on the load terminals (at the point of load connection) is showed in the paper. It is proved that in asymmetrical modes of three-phase power supply system operation the placement of phase voltage sensors on load terminals leads to a decrease in the efficiency, shift coefficient and an increase in the THD of a network phase voltages and currents in comparison with the second case. The developed theoretical propositions using the modeling of power supply system with power active filter in Matlab environment are confirmed.