Injected Currents Of Controlled AC/DC Converters for Harmonic Analysis In Industrial Power Plants

M. Grotzbach, W. Frankenberg
{"title":"Injected Currents Of Controlled AC/DC Converters for Harmonic Analysis In Industrial Power Plants","authors":"M. Grotzbach, W. Frankenberg","doi":"10.1109/ICHPS.1992.559005","DOIUrl":null,"url":null,"abstract":"An easy method for predetermining the injected current harmonics of current-controlled six-pulse bridge converters is proposed. The parameters considered are the operating point of the converter, given by the DC mean current I/sub d/ and EMF E, and two circuit parameters, AC network and DC reactance. When starting the predetermination, the operating point and the effective DC reactance have to be determined from the requirements of the applied DC loads. This leads to a uniform investigation of the controlled converter based on preliminary investigation reported elsewhere. As a result of systematic evaluations, the normalized line current harmonics are obtained graphically in the usual range of the parameters considered. >","PeriodicalId":438464,"journal":{"name":"ICHPS V International Conference on Harmonics in Power Systems.","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICHPS V International Conference on Harmonics in Power Systems.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHPS.1992.559005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

An easy method for predetermining the injected current harmonics of current-controlled six-pulse bridge converters is proposed. The parameters considered are the operating point of the converter, given by the DC mean current I/sub d/ and EMF E, and two circuit parameters, AC network and DC reactance. When starting the predetermination, the operating point and the effective DC reactance have to be determined from the requirements of the applied DC loads. This leads to a uniform investigation of the controlled converter based on preliminary investigation reported elsewhere. As a result of systematic evaluations, the normalized line current harmonics are obtained graphically in the usual range of the parameters considered. >
用于工业发电厂谐波分析的可控交直流变流器注入电流
提出了一种简便的电流控制六脉冲桥式变换器注入电流谐波的预估方法。考虑的参数是变换器的工作点,由直流平均电流I/sub d/和EMF E给出,以及两个电路参数,交流网络和直流电抗。在开始预定时,工作点和有效直流电抗必须根据所施加的直流负载的要求确定。这导致基于其他地方报道的初步调查的受控变流器的统一调查。作为系统评价的结果,在通常考虑的参数范围内得到归一化的线电流谐波。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信