Letters to the Editors

T. Petty, R. Cherniack
{"title":"Letters to the Editors","authors":"T. Petty, R. Cherniack","doi":"10.1055/s-2007-1012163","DOIUrl":null,"url":null,"abstract":"To the Editors In reference to Dr. Gerald Bristow's article in the July, 1980 issue of Seminars in Respiratory Medicine, Volume 2, Number 1, entitled \"Oxygen Therapy.\" He stated that it is important to recognize that with the venturi mask system the concentration of oxygen inhaled by the patient will usually be lower than the set on the manifold of the venturi mask system because of entrainment of room air through the side holes in the mask or between the face and the mask. This information is incorrect. Venturi-style masks are designed to deliver precise oxygen concentration and as a result of their accuracy, are a valuable tool in treating patients with chronic lung disease. Their precision occurs due to the high total flow of gas into the mask thereby nullifying any inherent leaks which occur in all masks. Specifications vary from one manufacturer to another but this list indicates approximate total flows to the mask at various concentrations:","PeriodicalId":311434,"journal":{"name":"Seminar in Respiratory Medicine","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1981-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminar in Respiratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-2007-1012163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To the Editors In reference to Dr. Gerald Bristow's article in the July, 1980 issue of Seminars in Respiratory Medicine, Volume 2, Number 1, entitled "Oxygen Therapy." He stated that it is important to recognize that with the venturi mask system the concentration of oxygen inhaled by the patient will usually be lower than the set on the manifold of the venturi mask system because of entrainment of room air through the side holes in the mask or between the face and the mask. This information is incorrect. Venturi-style masks are designed to deliver precise oxygen concentration and as a result of their accuracy, are a valuable tool in treating patients with chronic lung disease. Their precision occurs due to the high total flow of gas into the mask thereby nullifying any inherent leaks which occur in all masks. Specifications vary from one manufacturer to another but this list indicates approximate total flows to the mask at various concentrations:
给编辑的信
致编辑:参考Gerald Bristow博士在1980年7月出版的《呼吸医学研讨会》第二卷第一篇题为“氧气疗法”的文章。他说,重要的是要认识到,使用文丘里面罩系统,患者吸入的氧气浓度通常会低于文丘里面罩系统歧管上的设置,因为室内空气会通过面罩的侧孔或面部与面罩之间夹带。这个信息不正确。文丘里式口罩旨在提供精确的氧气浓度,由于其准确性,是治疗慢性肺病患者的宝贵工具。它们的精度是由于进入面罩的气体总流量高,从而消除了所有面罩中发生的任何固有泄漏。规格因制造商而异,但此列表显示了不同浓度下面罩的大致总流量:
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信