{"title":"Repetitive control of an active filter under varying network frequency: Power factor correction","authors":"G. Ramos, J. M. Olm, R. Costa-Castelló","doi":"10.1109/LARC.2011.6086827","DOIUrl":null,"url":null,"abstract":"This work deals with the design and analysis of a controller for a shunt active power filter. The design is based on combined feedforward and feedback actions, the last using repetitive control and aimed at obtaining a good closed-loop performance in spite of the possible frequency variations that may occur in the electrical network. These changes affect the performance of the controller which, for the active filter application, can be seen as a degradation of the power factor in case of reactive loads. To overcome this problem a compensation technique consisting of adapting the sampling rate of the controller according to the network frequency variation is proposed. Experimental results indicate good performance of the closed-loop system preserving a unitary power factor for different network frequencies.","PeriodicalId":419849,"journal":{"name":"IX Latin American Robotics Symposium and IEEE Colombian Conference on Automatic Control, 2011 IEEE","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IX Latin American Robotics Symposium and IEEE Colombian Conference on Automatic Control, 2011 IEEE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LARC.2011.6086827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This work deals with the design and analysis of a controller for a shunt active power filter. The design is based on combined feedforward and feedback actions, the last using repetitive control and aimed at obtaining a good closed-loop performance in spite of the possible frequency variations that may occur in the electrical network. These changes affect the performance of the controller which, for the active filter application, can be seen as a degradation of the power factor in case of reactive loads. To overcome this problem a compensation technique consisting of adapting the sampling rate of the controller according to the network frequency variation is proposed. Experimental results indicate good performance of the closed-loop system preserving a unitary power factor for different network frequencies.
有源滤波器在变网络频率下的重复控制:功率因数校正
本文研究了并联型有源电力滤波器控制器的设计与分析。该设计基于前馈和反馈相结合的动作,后者使用重复控制,旨在尽管电网中可能发生频率变化,但仍能获得良好的闭环性能。这些变化会影响控制器的性能,对于有源滤波器应用,可以看作是无功负载情况下功率因数的退化。为了克服这一问题,提出了一种根据网络频率变化调整控制器采样率的补偿技术。实验结果表明,该闭环系统在不同网络频率下均能保持统一的功率因数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信