Different approaches to increase resolution in DHM

A. Faridian, D. Hopp, G. Pedrini, W. Osten, U. Eigenthaler, M. Hirscher
{"title":"Different approaches to increase resolution in DHM","authors":"A. Faridian, D. Hopp, G. Pedrini, W. Osten, U. Eigenthaler, M. Hirscher","doi":"10.1109/WIO.2010.5582503","DOIUrl":null,"url":null,"abstract":"Different approaches to increase the resolution in digital holographic microscopy (DHM) are presented. A high resolution approach has been implemented in the off axis Deep UV DHM setup using oblique illumination to overcome the limitation introduced by the optical system and the theoretical resolution limit of 250 nm (according to Abbe criterion) has been verified, experimentally. A two view DHM system operating in the visible wavelength is also introduced to increase the resolution and contrast in 3D imaging of complex biological samples.","PeriodicalId":201478,"journal":{"name":"2010 9th Euro-American Workshop on Information Optics","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th Euro-American Workshop on Information Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WIO.2010.5582503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Different approaches to increase the resolution in digital holographic microscopy (DHM) are presented. A high resolution approach has been implemented in the off axis Deep UV DHM setup using oblique illumination to overcome the limitation introduced by the optical system and the theoretical resolution limit of 250 nm (according to Abbe criterion) has been verified, experimentally. A two view DHM system operating in the visible wavelength is also introduced to increase the resolution and contrast in 3D imaging of complex biological samples.
提高DHM分辨率的不同方法
提出了提高数字全息显微镜(DHM)分辨率的不同方法。在离轴深紫外DHM装置中实现了一种高分辨率的方法,使用倾斜照明克服了光学系统引入的限制,并通过实验验证了250 nm的理论分辨率极限(根据阿贝准则)。为了提高复杂生物样品三维成像的分辨率和对比度,还介绍了一种工作在可见光波段的双视图DHM系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信