{"title":"Use of low-pass filters to protect equipment from transient overvoltages on the mains","authors":"R. B. Standler","doi":"10.1109/ICPS.1988.10979","DOIUrl":null,"url":null,"abstract":"The design of commercial low-pass filter modules for equipment connected to the low-voltage supply mains is reviewed. Problems of using these filters to protect electronic equipment from damage or upset by high-voltage transients on the mains are discussed. The design and performance of circuits that incorporate both overvoltage protection and a low-pass filter are discussed. One circuit is designed for commercial environments, the other of medical equipment in patient care areas. Filters for medical equipment in patient care areas must have very small line-to-ground leakage currents, which make it difficult to provide either overvoltage protection or low-pass filtering. Using an overvoltage-protection low-pass filter is less expensive than using a line conditioner to protect equipment, and, in many instances, the filter may give satisfactory protection.<<ETX>>","PeriodicalId":201639,"journal":{"name":"Conference Record, Industrial and Commercial Power Systems Technical Conference, 1988.","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record, Industrial and Commercial Power Systems Technical Conference, 1988.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1988.10979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The design of commercial low-pass filter modules for equipment connected to the low-voltage supply mains is reviewed. Problems of using these filters to protect electronic equipment from damage or upset by high-voltage transients on the mains are discussed. The design and performance of circuits that incorporate both overvoltage protection and a low-pass filter are discussed. One circuit is designed for commercial environments, the other of medical equipment in patient care areas. Filters for medical equipment in patient care areas must have very small line-to-ground leakage currents, which make it difficult to provide either overvoltage protection or low-pass filtering. Using an overvoltage-protection low-pass filter is less expensive than using a line conditioner to protect equipment, and, in many instances, the filter may give satisfactory protection.<>
使用低通滤波器保护设备免受市电瞬态过电压的影响
对连接到低压电源的设备的商用低通滤波器模块的设计进行了综述。讨论了使用这些滤波器保护电子设备免受高压瞬变损坏或扰乱的问题。讨论了过压保护和低通滤波器电路的设计和性能。一个电路是为商业环境设计的,另一个电路是为病人护理领域的医疗设备设计的。用于患者护理区域的医疗设备的滤波器必须具有非常小的线对地泄漏电流,这使得难以提供过压保护或低通滤波。使用过压保护低通滤波器比使用线路调节器来保护设备更便宜,并且在许多情况下,滤波器可以提供令人满意的保护
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信