{"title":"Slab Co, Lasers Excited By All Solid State Rf Generators","authors":"S. Kobayashi, T. Murata, K. Terai","doi":"10.1109/CLEOPR.1997.610577","DOIUrl":null,"url":null,"abstract":"Water-operated heat exchanger since line-narrowed outputs can be obtained maintaining the continuous wavelength tunability. In this paper, we demonstrate 10 GHz active frequency shift using a high-pressure CO, laser. The experimental apparatus is shown in Fig. 1. The main section of the system was an injection-locked high-pressure CO, laser with a gain volume of 1 X 1 X 30 cm’. The laser can operate at a pressure up to 10 atm. Then, the maximum input energy density was 1000 J/t. In addition to a main cavity consisting of a rear reflector (RR) and an output coupler (OC), a subcavity was constructed by the RR and a total reflector (TR). The RR was mounted on the laser tube in order to shorten the cavity length. The lengths of the main cavity and the subcavity were 95 cm and 105 cm, respectively. An A 0 frequency shifter instaIled in the subcavity was driven at a frequency of 40 MHz. The experiment was carried out at around the 1OP (20) line since no dispersive element for coarse tuning was used. Figure 2 shows the frequency shift as a function of the gate pulse width of the PC. The slope of 9.5 GHz/ ks agreed well with the value of 9.4 GHz/ks calculated from the round-trip frequency shift of 80 MHz and the round-trip time of 8.5 ns in the subcavity. The maximum frequency shift obtained was 9 GHz at a pressure of 8 atm. At higher pressures the maximum frequency shift was decreased by the reduction of the gain duration time although the gain bandwidth became wider. In order tu select other wavelength regions, we replaced the RR by a low-dispersive (50 lines/”) diffraction grating. The frequency shift was successfully obtained without degrading the tuning linearity and the maximum frequency shift. “Department of Physics, Science University of Tokyo, 1-3 Kagurazaka, Shinjyuku-ku, Tokyo 262, IAPAN","PeriodicalId":260495,"journal":{"name":"Technical Digest CLEO/Pacific Rim '97 Pacific Rim Conference on Lasers and Electro-Optics","volume":"228 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Digest CLEO/Pacific Rim '97 Pacific Rim Conference on Lasers and Electro-Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOPR.1997.610577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Water-operated heat exchanger since line-narrowed outputs can be obtained maintaining the continuous wavelength tunability. In this paper, we demonstrate 10 GHz active frequency shift using a high-pressure CO, laser. The experimental apparatus is shown in Fig. 1. The main section of the system was an injection-locked high-pressure CO, laser with a gain volume of 1 X 1 X 30 cm’. The laser can operate at a pressure up to 10 atm. Then, the maximum input energy density was 1000 J/t. In addition to a main cavity consisting of a rear reflector (RR) and an output coupler (OC), a subcavity was constructed by the RR and a total reflector (TR). The RR was mounted on the laser tube in order to shorten the cavity length. The lengths of the main cavity and the subcavity were 95 cm and 105 cm, respectively. An A 0 frequency shifter instaIled in the subcavity was driven at a frequency of 40 MHz. The experiment was carried out at around the 1OP (20) line since no dispersive element for coarse tuning was used. Figure 2 shows the frequency shift as a function of the gate pulse width of the PC. The slope of 9.5 GHz/ ks agreed well with the value of 9.4 GHz/ks calculated from the round-trip frequency shift of 80 MHz and the round-trip time of 8.5 ns in the subcavity. The maximum frequency shift obtained was 9 GHz at a pressure of 8 atm. At higher pressures the maximum frequency shift was decreased by the reduction of the gain duration time although the gain bandwidth became wider. In order tu select other wavelength regions, we replaced the RR by a low-dispersive (50 lines/”) diffraction grating. The frequency shift was successfully obtained without degrading the tuning linearity and the maximum frequency shift. “Department of Physics, Science University of Tokyo, 1-3 Kagurazaka, Shinjyuku-ku, Tokyo 262, IAPAN
水操作的热交换器,因为线窄输出可以获得保持连续的波长可调性。在本文中,我们演示了使用高压一氧化碳激光器的10ghz有源频移。实验装置如图1所示。该系统的主要部分是一个增益体积为1 X 1 X 30 cm '的注入锁定高压一氧化碳激光器。激光器可以在高达10atm的压力下工作。此时,最大输入能量密度为1000 J/t。除了由后反射器(RR)和输出耦合器(OC)组成的主腔外,还由后反射器和总反射器(TR)组成子腔。为了缩短腔体长度,将激光管安装在激光管上。主腔体长度为95 cm,亚腔体长度为105 cm。安装在亚腔内的a0移频器以40mhz的频率驱动。由于没有使用用于粗调谐的色散元件,因此实验在1OP(20)线附近进行。图2显示了频移作为PC的门脉宽的函数。9.5 GHz/ks的斜率与由80 MHz的往返频移和8.5 ns的往返时间计算得到的9.4 GHz/ks值吻合得很好。在8atm压力下获得的最大频移为9ghz。在较高的压力下,增益持续时间的减少降低了最大频移,尽管增益带宽变宽了。为了选择其他波长区域,我们用低色散(50线/”)衍射光栅代替了RR。在不降低调谐线性度和最大频移的情况下,成功地获得了频移。东京理科大学物理系,新宿区神乐坂1-3,东京262,IAPAN