Image Denoising Technique for CT Dose Modulation

Haneen A. Elyamani, S. El-Seoud, E. Rashed
{"title":"Image Denoising Technique for CT Dose Modulation","authors":"Haneen A. Elyamani, S. El-Seoud, E. Rashed","doi":"10.1145/3220267.3220288","DOIUrl":null,"url":null,"abstract":"Low-dose computed tomography (LDCT) imaging is considerably recommended for use in clinical CT scanning because of growing fears over excessive radiation exposure. Automatic exposure control (AEC) is one of the methods used in dose reduction techniques that have been implemented clinically comprise showing significant decrease scan range. The quality of some images may be roughly degraded with noise and streak artifacts due to x-ray flux, based on modulating radiation dose in the angular and slice directions. In 2005, the nonlocal means (NLM) algorithm showed high performance in denoising images corrupted by LDCT. The proposed method incorporates a prior knowledge obtained from previous high-quality CT slices to improve low-quality CT slice during the filtering process because of the anatomical similarity between the arranged image slices of the scans. The proposed method is evaluated using real data and CT image quality is notably improved.","PeriodicalId":177522,"journal":{"name":"International Conference on Software and Information Engineering","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Software and Information Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3220267.3220288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Low-dose computed tomography (LDCT) imaging is considerably recommended for use in clinical CT scanning because of growing fears over excessive radiation exposure. Automatic exposure control (AEC) is one of the methods used in dose reduction techniques that have been implemented clinically comprise showing significant decrease scan range. The quality of some images may be roughly degraded with noise and streak artifacts due to x-ray flux, based on modulating radiation dose in the angular and slice directions. In 2005, the nonlocal means (NLM) algorithm showed high performance in denoising images corrupted by LDCT. The proposed method incorporates a prior knowledge obtained from previous high-quality CT slices to improve low-quality CT slice during the filtering process because of the anatomical similarity between the arranged image slices of the scans. The proposed method is evaluated using real data and CT image quality is notably improved.
CT剂量调制图像去噪技术
低剂量计算机断层扫描(LDCT)被广泛推荐用于临床CT扫描,因为人们越来越担心过度的辐射暴露。自动暴露控制(AEC)是临床实施的剂量减少技术中使用的方法之一,包括显示显着降低扫描范围。基于角方向和切片方向的调制辐射剂量,由于x射线通量的影响,某些图像的质量可能会受到噪声和条纹伪影的影响。2005年,非局部均值(nonlocal means, NLM)算法在去噪LDCT损坏图像方面表现出优异的性能。该方法结合了从以前的高质量CT切片中获得的先验知识,以改善在滤波过程中由于扫描图像切片之间排列的解剖相似性而导致的低质量CT切片。用实际数据对该方法进行了评价,结果表明,该方法显著提高了CT图像质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信