Structure Design Modification of DPW Nasdem Office Building using Steel Special Moment Resisting Frame

Putri Aru Anjani, R. Bakri, Y. Tethool
{"title":"Structure Design Modification of DPW Nasdem Office Building using Steel Special Moment Resisting Frame","authors":"Putri Aru Anjani, R. Bakri, Y. Tethool","doi":"10.30862/jistech.v12i1.206","DOIUrl":null,"url":null,"abstract":"Manokwari is a District located at the junction of three main plates forming the earth's crust, namely the pacific plate. This makes Manokwari Regency prone to earthquakes. Therefore, building planning must be designed with the concept of earthquake-resistant buildings. Steel material is one type of material that is often used for planning earthquake-resistant building structures because it has high strength and lightweight properties that it is good for earthquake-resistant buildings. One of the methods often used in the planning of earthquake-resistant steel structures is the special moment resisting frame system (SMRF). This structural system is used because it has full ductility that it can survive in areas with a high earthquake risk. This planning modification was carried out at the DPW NasDem Office building by changing the main structure in the form of reinforced concrete using a steel structure with a special moment resisting frame system (SMRF). Based on the calculation and analysis, the results were obtained, namely: the dimensions of the secondary beam are IWF 300x150x6.5x9, the main beam 1 IWF 350x250x9x14, the main beam 2 IWF 300x200x9x14, the column dimensions KC 450x200x9x14 (floors 1-3), KC 400x200x8x13 (floors 4-5), and KC 350x175x7x11 (elevator columns). Floor slabs are 12 cm thick and 10 cm thick for roofing plates. The SRMF joint design uses a high-quality bolt (A325) with the quality of the BJ41 joint plate and the planning results meet the requirements.","PeriodicalId":180454,"journal":{"name":"JISTECH: Journal of Information Science and Technology","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JISTECH: Journal of Information Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30862/jistech.v12i1.206","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Manokwari is a District located at the junction of three main plates forming the earth's crust, namely the pacific plate. This makes Manokwari Regency prone to earthquakes. Therefore, building planning must be designed with the concept of earthquake-resistant buildings. Steel material is one type of material that is often used for planning earthquake-resistant building structures because it has high strength and lightweight properties that it is good for earthquake-resistant buildings. One of the methods often used in the planning of earthquake-resistant steel structures is the special moment resisting frame system (SMRF). This structural system is used because it has full ductility that it can survive in areas with a high earthquake risk. This planning modification was carried out at the DPW NasDem Office building by changing the main structure in the form of reinforced concrete using a steel structure with a special moment resisting frame system (SMRF). Based on the calculation and analysis, the results were obtained, namely: the dimensions of the secondary beam are IWF 300x150x6.5x9, the main beam 1 IWF 350x250x9x14, the main beam 2 IWF 300x200x9x14, the column dimensions KC 450x200x9x14 (floors 1-3), KC 400x200x8x13 (floors 4-5), and KC 350x175x7x11 (elevator columns). Floor slabs are 12 cm thick and 10 cm thick for roofing plates. The SRMF joint design uses a high-quality bolt (A325) with the quality of the BJ41 joint plate and the planning results meet the requirements.
DPW纳斯达克办公大楼钢特抗弯矩框架结构设计改造
马诺瓦里是一个位于形成地壳的三个主要板块,即太平洋板块交界处的地区。这使得马诺瓦里摄政容易发生地震。因此,建筑规划设计必须以抗震建筑为理念。钢材料是一种经常用于规划抗震建筑结构的材料,因为它具有高强度和轻量化的特性,有利于抗震建筑。特殊抗弯矩框架体系是钢结构抗震设计中常用的方法之一。使用这种结构体系是因为它具有充分的延展性,可以在地震风险高的地区生存。这个规划修改是在DPW NasDem办公楼进行的,通过使用具有特殊抗弯矩框架系统(SMRF)的钢结构改变钢筋混凝土形式的主要结构。通过计算分析得出:副梁尺寸为IWF 300x150x6.5x9,主梁尺寸为1 IWF 350x250x9x14,主梁尺寸为2 IWF 300x200x9x14,柱尺寸为KC 450x200x9x14(1-3层),KC 400x200x8x13(4-5层),KC 350x175x7x11(电梯柱)。楼板厚12厘米,屋面板厚10厘米。SRMF接头设计采用优质螺栓(A325),配合BJ41接头板的质量,规划结果满足要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信