A Comparison of the Results between Internal Fixation and External Fixation in AO C Type Distal Radius Fractures

Yoon-Min Lee, H. Lee, Seok-Whan Song, Jae-Hoon Choi, Jong-Tae Park
{"title":"A Comparison of the Results between Internal Fixation and External Fixation in AO C Type Distal Radius Fractures","authors":"Yoon-Min Lee, H. Lee, Seok-Whan Song, Jae-Hoon Choi, Jong-Tae Park","doi":"10.12671/JKFS.2018.31.3.87","DOIUrl":null,"url":null,"abstract":"Financial support: None. Conflict of interests: None. Purpose: The purpose of this study was to evaluate the radiological and clinical results of plate fixation and external fixation with additional devices for treating distal radius fracture in AO type C subtypes, and propose a treatment method according to the subtypes. Materials and Methods: Two hundred and one AO type C distal radius fracture patients were retrospectively reviewed. Eighty-five patients in group 1 were treated with volar or dorsal plate, and 116 patients in group 2, were treated with external fixation with additional fixation devices. Clinical (range of mtion, Green and O’Brien’s score) and radiological outcomes were evaluated. Results: At the 12-month follow-up, group 1 showed flexion of 64.4, extension of 68.3, ulnar deviation of 30.6, radial deviation of 20.8, supination of 76.1, and pronation of 79.4 in average; group 2 showed flexion of 60.5, extension of 66.9, ulnar deviation of 25.5, radial deviation of 18.6, supination of 73.5, and pronation of 75.0 in average. The mean Green and O’Brien score was 92.2 in group 1 and 88.6 in group 2. The radial height of group 1 and group 2 was 11.6/11.4 mm; radial inclination was 23.2/ 22.5; volar tilt was 11.6/ 8.7; and the ulnar displacement was 1.27/0.93 mm. Conclusion: Judicious surgical techniques during device application and tips for postoperative management during external fixation can produce similar clinical results compared with internal fixation patients.","PeriodicalId":436464,"journal":{"name":"Journal of the Korean Fracture Society","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Fracture Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12671/JKFS.2018.31.3.87","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Financial support: None. Conflict of interests: None. Purpose: The purpose of this study was to evaluate the radiological and clinical results of plate fixation and external fixation with additional devices for treating distal radius fracture in AO type C subtypes, and propose a treatment method according to the subtypes. Materials and Methods: Two hundred and one AO type C distal radius fracture patients were retrospectively reviewed. Eighty-five patients in group 1 were treated with volar or dorsal plate, and 116 patients in group 2, were treated with external fixation with additional fixation devices. Clinical (range of mtion, Green and O’Brien’s score) and radiological outcomes were evaluated. Results: At the 12-month follow-up, group 1 showed flexion of 64.4, extension of 68.3, ulnar deviation of 30.6, radial deviation of 20.8, supination of 76.1, and pronation of 79.4 in average; group 2 showed flexion of 60.5, extension of 66.9, ulnar deviation of 25.5, radial deviation of 18.6, supination of 73.5, and pronation of 75.0 in average. The mean Green and O’Brien score was 92.2 in group 1 and 88.6 in group 2. The radial height of group 1 and group 2 was 11.6/11.4 mm; radial inclination was 23.2/ 22.5; volar tilt was 11.6/ 8.7; and the ulnar displacement was 1.27/0.93 mm. Conclusion: Judicious surgical techniques during device application and tips for postoperative management during external fixation can produce similar clinical results compared with internal fixation patients.
aoc型桡骨远端骨折内固定与外固定效果比较
资金支持:无。利益冲突:无。目的:本研究的目的是评价钢板内固定和附加装置外固定治疗AO型C亚型桡骨远端骨折的放射学和临床效果,并根据不同亚型提出治疗方法。材料与方法:回顾性分析201例AO C型桡骨远端骨折患者的临床资料。第1组85例患者采用掌侧或背侧钢板治疗,第2组116例患者采用外固定外加固定装置治疗。评估临床(活动范围,Green和O 'Brien评分)和放射学结果。结果:随访12个月,1组屈曲64.4,伸直68.3,尺偏30.6,桡骨偏20.8,旋后76.1,旋前79.4;2组平均屈曲60.5,伸直66.9,尺偏25.5,桡骨偏18.6,旋后73.5,旋前75.0。第一组的Green和O 'Brien平均评分为92.2分,第二组为88.6分。组1、组2径向高度为11.6/11.4 mm;径向倾角为23.2/ 22.5;掌侧倾角为11.6/ 8.7;尺侧位移为1.27/0.93 mm。结论:外固定术中合理的使用器械的手术技巧和术后处理技巧,与内固定术患者的临床效果相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信