Partial Discharge Inception Voltage in DC insulation systems: a comparison with AC voltage supply

P. Seri, L. Cirioni, H. Naderiallaf, G. Montanari, R. Hebner, A. Gattozzi, Xianyong Feng
{"title":"Partial Discharge Inception Voltage in DC insulation systems: a comparison with AC voltage supply","authors":"P. Seri, L. Cirioni, H. Naderiallaf, G. Montanari, R. Hebner, A. Gattozzi, Xianyong Feng","doi":"10.1109/EIC43217.2019.9046630","DOIUrl":null,"url":null,"abstract":"In this paper the AC and DC partial discharge inception voltages, PDIV, are modeled and validated through measurements performed on multi-layer flat specimens with artificial defects. The results highlight that, depending on temperature and material conductivity, there can be a large difference between PDIV under DC and AC, which depends on insulation temperature, thus, e.g., cable loading. Indeed PDIV-DC can be much larger than PDIV-AC at room temperature, but the two values can be very close (with PDIV -DC being even smaller than PDIV-AC) at maximum operating temperature, i.e. full load.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

In this paper the AC and DC partial discharge inception voltages, PDIV, are modeled and validated through measurements performed on multi-layer flat specimens with artificial defects. The results highlight that, depending on temperature and material conductivity, there can be a large difference between PDIV under DC and AC, which depends on insulation temperature, thus, e.g., cable loading. Indeed PDIV-DC can be much larger than PDIV-AC at room temperature, but the two values can be very close (with PDIV -DC being even smaller than PDIV-AC) at maximum operating temperature, i.e. full load.
直流绝缘系统的局部放电起始电压:与交流电源的比较
本文建立了交流和直流局部放电起始电压PDIV模型,并通过对带有人工缺陷的多层平面试件进行了测量验证。结果强调,根据温度和材料电导率,直流和交流下的PDIV之间可能存在很大差异,这取决于绝缘温度,因此,例如电缆负载。事实上,PDIV-DC在室温下可能比PDIV- ac大得多,但在最高工作温度下,即满载时,这两个值可能非常接近(PDIV-DC甚至比PDIV- ac小)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信