The resolute Onyx drug eluting stent for neurointervention: A technical series.

T. White, K. Shah, P. Koul, T. Link, A. Dehdashti, J. Katz, A. Patsalides, H. Woo
{"title":"The resolute Onyx drug eluting stent for neurointervention: A technical series.","authors":"T. White, K. Shah, P. Koul, T. Link, A. Dehdashti, J. Katz, A. Patsalides, H. Woo","doi":"10.1177/15910199221084398","DOIUrl":null,"url":null,"abstract":"INTRODUCTION\nCurrent methods for angioplasty and stenting of the intracranial vasculature for neurointervention are limited. The Wingspan Stent System is Food and Drug Administration (FDA) approved with human device exemption for a limited patient group and despite numerous prospective registries and trials demonstrating reasonable safety, still carries warnings from the FDA for its use. Given these limitations, we present the technical nuances and outcomes of the off-label use of the Resolute Onyx drug-eluting stent (DES) for neurointerventional purposes.\n\n\nMETHODS\nRetrospective chart review of all patients undergoing a neurointerventional procedure with the Resolute Onyx DES was done from January 2017-2021. The Resolute Onyx is a coronary balloon-mounted drug-eluting (zotarolimus) single wire laser cut stent. Technical details and procedural outcomes were collected.\n\n\nRESULTS\nIn total 40 patients had attempted placement of the Resolute Onyx DES with procedural success in 95% of patients. The most common vessel stented was the basilar artery, 30% (12/40). The most common indication was intracranial atherosclerotic disease in 62.5% (25/40) patients, followed by acute stroke in 17.5% (7/40) of patients. The technical and procedural outcomes were excellent with only one technical complication (2.5%).\n\n\nCONCLUSIONS\nThis series describes the initial technical safety and utility of utilizing a new generation balloon-mounted drug-eluting stent for neurointerventional purposes. This stent offers the potential for improved navigability, delivery, and outcomes compared to current neurointerventional options and warrants further study.","PeriodicalId":126264,"journal":{"name":"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15910199221084398","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

INTRODUCTION Current methods for angioplasty and stenting of the intracranial vasculature for neurointervention are limited. The Wingspan Stent System is Food and Drug Administration (FDA) approved with human device exemption for a limited patient group and despite numerous prospective registries and trials demonstrating reasonable safety, still carries warnings from the FDA for its use. Given these limitations, we present the technical nuances and outcomes of the off-label use of the Resolute Onyx drug-eluting stent (DES) for neurointerventional purposes. METHODS Retrospective chart review of all patients undergoing a neurointerventional procedure with the Resolute Onyx DES was done from January 2017-2021. The Resolute Onyx is a coronary balloon-mounted drug-eluting (zotarolimus) single wire laser cut stent. Technical details and procedural outcomes were collected. RESULTS In total 40 patients had attempted placement of the Resolute Onyx DES with procedural success in 95% of patients. The most common vessel stented was the basilar artery, 30% (12/40). The most common indication was intracranial atherosclerotic disease in 62.5% (25/40) patients, followed by acute stroke in 17.5% (7/40) of patients. The technical and procedural outcomes were excellent with only one technical complication (2.5%). CONCLUSIONS This series describes the initial technical safety and utility of utilizing a new generation balloon-mounted drug-eluting stent for neurointerventional purposes. This stent offers the potential for improved navigability, delivery, and outcomes compared to current neurointerventional options and warrants further study.
神经介入用resolute Onyx药物洗脱支架:技术系列。
目前用于神经介入的颅内血管成形术和支架置入的方法是有限的。翼展支架系统是美国食品和药物管理局(FDA)批准的人体设备豁免,用于有限的患者群体,尽管大量的前瞻性注册和试验证明了合理的安全性,但FDA仍然对其使用发出警告。鉴于这些限制,我们提出了Resolute Onyx药物洗脱支架(DES)用于神经介入目的的技术上的细微差别和结果。方法回顾性分析2017-2021年1月使用Resolute Onyx DES进行神经介入手术的所有患者的图表。Resolute Onyx是冠状动脉球囊安装药物洗脱(佐他莫司)单丝激光切割支架。收集了技术细节和程序结果。结果共40例患者尝试放置Resolute Onyx DES, 95%的患者手术成功。最常见的血管支架是基底动脉,占30%(12/40)。62.5%(25/40)的患者最常见的适应症是颅内动脉粥样硬化疾病,其次是17.5%(7/40)的患者急性脑卒中。技术和手术结果均良好,仅有一例技术并发症(2.5%)。本系列文章描述了新一代球囊式药物洗脱支架用于神经介入目的的初步技术安全性和实用性。与目前的神经介入治疗方案相比,该支架提供了改善可导航性、运送和预后的潜力,值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信