Visualization and rapid quantification of autoradiographic labeling in scanning electron microscopy applied to localization of receptor sites on the surface of whole cells.

C Péchoux, J Boumendil, D Dolbeau, C Souchier, L Frappart
{"title":"Visualization and rapid quantification of autoradiographic labeling in scanning electron microscopy applied to localization of receptor sites on the surface of whole cells.","authors":"C Péchoux,&nbsp;J Boumendil,&nbsp;D Dolbeau,&nbsp;C Souchier,&nbsp;L Frappart","doi":"10.1007/BF02899707","DOIUrl":null,"url":null,"abstract":"<p><p>The use of backscattered electron imaging (BEI) as a routine procedure for examining autoradiographic reactions in scanning electron microscopy (SEM) is described. This technique allows the determination of the number of receptor sites occupied by 125I-epidermal growth factor (EGF) on whole cells. The effect of 1.25 dihydroxyvitamin D3 (1,25 (OH)2D3) on the number of epidermal growth factor receptors (EGF-R) in the BT 20 human mammary carcinoma cell line (which is known to possess a very high number of EGF-R) has been evaluated with this method. To compare the silver grain density over the cells (controls and 1,25 (OH)2D3-treated cells) we used an image analysis system Quantimet 900. The results were compared with those of a previous study using transmission electron microscopy (TEM). This study confirmed the results obtained with TEM and showed the even distribution of receptors sites on a single cell and a large difference in the number of receptor sites from one cell to another. The use of BEI to visualize the autoradiographic reaction in SEM allowed the examination of a large surface with good contrast and resolution and eliminated artefacts not corresponding to the silver grains. It gave new information not delivered by quantitative TEM autoradiography and was easier and faster to use. The efficient use of SEM autoradiography combined with BEI could facilitate whole area distribution mapping of radioactive labeling.</p>","PeriodicalId":23521,"journal":{"name":"Virchows Archiv. B, Cell pathology including molecular pathology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02899707","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Virchows Archiv. B, Cell pathology including molecular pathology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02899707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The use of backscattered electron imaging (BEI) as a routine procedure for examining autoradiographic reactions in scanning electron microscopy (SEM) is described. This technique allows the determination of the number of receptor sites occupied by 125I-epidermal growth factor (EGF) on whole cells. The effect of 1.25 dihydroxyvitamin D3 (1,25 (OH)2D3) on the number of epidermal growth factor receptors (EGF-R) in the BT 20 human mammary carcinoma cell line (which is known to possess a very high number of EGF-R) has been evaluated with this method. To compare the silver grain density over the cells (controls and 1,25 (OH)2D3-treated cells) we used an image analysis system Quantimet 900. The results were compared with those of a previous study using transmission electron microscopy (TEM). This study confirmed the results obtained with TEM and showed the even distribution of receptors sites on a single cell and a large difference in the number of receptor sites from one cell to another. The use of BEI to visualize the autoradiographic reaction in SEM allowed the examination of a large surface with good contrast and resolution and eliminated artefacts not corresponding to the silver grains. It gave new information not delivered by quantitative TEM autoradiography and was easier and faster to use. The efficient use of SEM autoradiography combined with BEI could facilitate whole area distribution mapping of radioactive labeling.

扫描电镜中应用于全细胞表面受体定位的放射自显影标记的可视化和快速定量。
描述了在扫描电子显微镜(SEM)中使用背散射电子成像(BEI)作为检查放射自显影反应的常规程序。该技术可以测定125i -表皮生长因子(EGF)在整个细胞上占据的受体位点的数量。用这种方法评价了1.25双羟基维生素D3 (1,25 (OH)2D3)对BT 20人乳腺癌细胞系(已知具有非常高的EGF-R数量)中表皮生长因子受体(EGF-R)数量的影响。为了比较细胞(对照和1,25 (OH) 2d3处理的细胞)上的银颗粒密度,我们使用了图像分析系统Quantimet 900。用透射电子显微镜(TEM)与先前的研究结果进行了比较。本研究证实了TEM得到的结果,表明受体位点在单个细胞上分布均匀,不同细胞间受体位点数量差异较大。利用BEI在SEM中可视化放射自成像反应,可以检查具有良好对比度和分辨率的大表面,并消除与银颗粒不对应的伪影。它提供了定量透射电镜放射自显像无法提供的新信息,使用起来更容易、更快捷。有效地利用扫描电镜放射自显影技术结合BEI,可以方便放射性标记的全区域分布作图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信