Mengmeng Cheng, Shuwen Guo, Bo Fan, Quan Wan, Zuxiang Wen, Dacheng Xu
{"title":"Automatic Mode-Matching and Scale Factor Adjustable Detection System for Force to Rebalance Control of Cobweb-Like Gyroscopes","authors":"Mengmeng Cheng, Shuwen Guo, Bo Fan, Quan Wan, Zuxiang Wen, Dacheng Xu","doi":"10.1109/ICSENS.2018.8589903","DOIUrl":null,"url":null,"abstract":"An automatic mode-matching circuit and scale factor adjustable detection system for force to rebalance cobweb-like disk resonator gyroscopes (DRG) are presented in this work. The mode-matching circuit uses a phase detection system to track and control phase difference between output signal of drive mode and quadrature error to match the mode resonance frequencies, which results in a significant performance improvement. Besides, a new scale factor adjustment method is proposed, which could be used in force to rebalance detection system of cobweb-like DRG. The experimental results show that the scale factor of gyroscope with closed loop controlled sense mode improves from 7.9mV/°/s to 19.1mV/°/s, and the bias instability improves from 11.19°/hr to O.43°/hr.","PeriodicalId":405874,"journal":{"name":"2018 IEEE SENSORS","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2018.8589903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
An automatic mode-matching circuit and scale factor adjustable detection system for force to rebalance cobweb-like disk resonator gyroscopes (DRG) are presented in this work. The mode-matching circuit uses a phase detection system to track and control phase difference between output signal of drive mode and quadrature error to match the mode resonance frequencies, which results in a significant performance improvement. Besides, a new scale factor adjustment method is proposed, which could be used in force to rebalance detection system of cobweb-like DRG. The experimental results show that the scale factor of gyroscope with closed loop controlled sense mode improves from 7.9mV/°/s to 19.1mV/°/s, and the bias instability improves from 11.19°/hr to O.43°/hr.