Falling Film Evaporation of HFO-1233zd(E) in Vertical Rectangular Minichannels Consisting of Serrated-Fins

J. Ohara
{"title":"Falling Film Evaporation of HFO-1233zd(E) in Vertical Rectangular Minichannels Consisting of Serrated-Fins","authors":"J. Ohara","doi":"10.1115/icnmm2019-4221","DOIUrl":null,"url":null,"abstract":"\n In the present study, the characteristics of heat transfer are experimentally investigated on the falling film evaporation of alternative pure refrigerant HFO-1233zd(E) in a plate-fin heat exchanger having a vertical rectangular minichannels of 2.11 mm hydraulic diameter consisting of serrated-fins. The refrigerant liquid is supplied to the channel through 37 holes of a liquid distributor. The liquid flowing down vertically is heated electrically from the rear wall of the channel and evaporated. The experimental parameters are as follows: the mass velocities are varied 7.4∼55.1 [kg/(m2s)], the heat fluxes are varied 8.7∼50 [kW/m2] and the pressures are about 100 [kPa].\n In the case of small mass velocity being smaller than 20 [kg/(m2s)], heat transfer coefficient decreases monotonously and gradually with increase of quality and take value of 5∼1[kW/m2K]. It is thought that the cause of lower value of heat transfer coefficient is occurring dry patch and aria enlargement of dry area in the downstream region. In the case of large mass velocity being larger than 41 [kg/(m2s)], the value of heat transfer coefficient becomes larger with increase of quality except for the case of mass velocity being 41 [kg/(m2s)] and heat flux being 50[kW/m2]. Improved heat transfer is to be thinkable that the liquid and vapor flow becomes dripping in the middle-stream region, and turns into mist flow with thin liquid film on the fin surface in the downstream region of quality being larger than 0.4.","PeriodicalId":221056,"journal":{"name":"ASME 2019 17th International Conference on Nanochannels, Microchannels, and Minichannels","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME 2019 17th International Conference on Nanochannels, Microchannels, and Minichannels","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/icnmm2019-4221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the present study, the characteristics of heat transfer are experimentally investigated on the falling film evaporation of alternative pure refrigerant HFO-1233zd(E) in a plate-fin heat exchanger having a vertical rectangular minichannels of 2.11 mm hydraulic diameter consisting of serrated-fins. The refrigerant liquid is supplied to the channel through 37 holes of a liquid distributor. The liquid flowing down vertically is heated electrically from the rear wall of the channel and evaporated. The experimental parameters are as follows: the mass velocities are varied 7.4∼55.1 [kg/(m2s)], the heat fluxes are varied 8.7∼50 [kW/m2] and the pressures are about 100 [kPa]. In the case of small mass velocity being smaller than 20 [kg/(m2s)], heat transfer coefficient decreases monotonously and gradually with increase of quality and take value of 5∼1[kW/m2K]. It is thought that the cause of lower value of heat transfer coefficient is occurring dry patch and aria enlargement of dry area in the downstream region. In the case of large mass velocity being larger than 41 [kg/(m2s)], the value of heat transfer coefficient becomes larger with increase of quality except for the case of mass velocity being 41 [kg/(m2s)] and heat flux being 50[kW/m2]. Improved heat transfer is to be thinkable that the liquid and vapor flow becomes dripping in the middle-stream region, and turns into mist flow with thin liquid film on the fin surface in the downstream region of quality being larger than 0.4.
HFO-1233zd(E)在锯齿形垂直矩形小通道中的降膜蒸发
实验研究了替代纯制冷剂HFO-1233zd(E)在水径为2.11 mm的锯齿翅片垂直矩形小通道板翅式换热器中的降膜蒸发换热特性。制冷剂液体通过液体分布器的37个孔进入通道。垂直向下流动的液体从通道的后壁被电加热并蒸发。实验参数为:质量速度为7.4 ~ 55.1 [kg/(m2s)],热流密度为8.7 ~ 50 [kW/m2],压力约为100 [kPa]。在质量速度小于20 [kg/(m2s)]的情况下,传热系数随质量的增加而单调递减,取5 ~ 1[kW/m2K]。换热系数降低的原因是下游地区出现了干斑和干流面积的扩大。在质量速度大于41 [kg/(m2s)]时,除质量速度为41 [kg/(m2s)]、热流密度为50[kW/m2]时外,传热系数随质量的增加而增大。改进的换热是可以想象的,在中游区域液体和蒸汽流动变成滴水,在质量大于0.4的下游区域变成薄雾流,在翅片表面形成薄的液膜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信