D. Pedersen, J. Callaghan, T. L. Johnston, G. Fetzer, R. Johnston
{"title":"Comparison of femoral head penetration rates between cementless acetabular components with 22-mm and 28-mm heads.","authors":"D. Pedersen, J. Callaghan, T. L. Johnston, G. Fetzer, R. Johnston","doi":"10.1054/ARTH.2001.28372","DOIUrl":null,"url":null,"abstract":"Between April 1993 and July 1994, the senior author (R.C.J.) performed 151 consecutive primary total hip arthroplasties using a Harris-Galante II acetabular component and a polished Iowa femoral component. In 105 hips, 22-mm head components were used, and in 46 hips, 28-mm head components were used. Femoral head penetration into the acetabular shell was measured using digital edge detection techniques. The group average penetration for the initial 2-year bedding-in period was 0.35 mm/y for the 22-mm and 0.31 mm/y for the 28-mm head components. The long-term rate of penetration into the shell was 0.11 mm/y for the 22-mm heads and 0.17 mm/y for the 28-mm heads, a significant difference (P=.029). The dislocation rate was significantly higher, however, with the 22-mm heads (P=.001). The 22-mm components showed significantly less wear but at the expense of an increase in the prevalence of dislocation.","PeriodicalId":280050,"journal":{"name":"The Journal of arthroplasty","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1054/ARTH.2001.28372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30
Abstract
Between April 1993 and July 1994, the senior author (R.C.J.) performed 151 consecutive primary total hip arthroplasties using a Harris-Galante II acetabular component and a polished Iowa femoral component. In 105 hips, 22-mm head components were used, and in 46 hips, 28-mm head components were used. Femoral head penetration into the acetabular shell was measured using digital edge detection techniques. The group average penetration for the initial 2-year bedding-in period was 0.35 mm/y for the 22-mm and 0.31 mm/y for the 28-mm head components. The long-term rate of penetration into the shell was 0.11 mm/y for the 22-mm heads and 0.17 mm/y for the 28-mm heads, a significant difference (P=.029). The dislocation rate was significantly higher, however, with the 22-mm heads (P=.001). The 22-mm components showed significantly less wear but at the expense of an increase in the prevalence of dislocation.