{"title":"Compatibility of tracer gases with oil/paper cable insulation","authors":"D. Couderc","doi":"10.1109/EEIC.1983.7465042","DOIUrl":null,"url":null,"abstract":"This paper describes the results of an investigation designed to evaluate the long-term compatibility of tracer gases with HPOF cable insulation in view of selecting one or several gases for the detection of leaks in underground cable networks. Accelerated aging was done on cable models with He, CF4, SF6, c-C4F8 and N2 gases dissolved in the oil. The aging was performed at 120°C with a voltage stress of 15 kv/mm and under a pressure of 238 kPa. The investigation included the observation of the dielectric losses variation with time, the measurement of the corona inception voltage, the ac breakdown of the samples as well as the detailed dissections of the cable models. The tests showed that the tracer gases other than helium performed at least as well as nitrogen, which has a long history of use in the field.","PeriodicalId":148370,"journal":{"name":"1983 EIC 6th Electrical/Electronical Insulation Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1983 EIC 6th Electrical/Electronical Insulation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.1983.7465042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the results of an investigation designed to evaluate the long-term compatibility of tracer gases with HPOF cable insulation in view of selecting one or several gases for the detection of leaks in underground cable networks. Accelerated aging was done on cable models with He, CF4, SF6, c-C4F8 and N2 gases dissolved in the oil. The aging was performed at 120°C with a voltage stress of 15 kv/mm and under a pressure of 238 kPa. The investigation included the observation of the dielectric losses variation with time, the measurement of the corona inception voltage, the ac breakdown of the samples as well as the detailed dissections of the cable models. The tests showed that the tracer gases other than helium performed at least as well as nitrogen, which has a long history of use in the field.
示踪气体与油/纸电缆绝缘的相容性
本文描述了一项旨在评估示踪气体与高温高压电缆绝缘长期相容性的调查结果,以选择一种或几种气体来检测地下电缆网络的泄漏。在油中溶解He、CF4、SF6、c-C4F8和N2气体,对电缆模型进行加速老化。老化温度为120℃,电压应力为15 kv/mm,压力为238 kPa。调查包括观察介质损耗随时间的变化,电晕起始电压的测量,样品的交流击穿以及电缆模型的详细解剖。测试表明,除氦以外的示踪气体的表现至少与氮气一样好,氮气在该领域有很长的使用历史。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书