Imaging the right ventricle in pulmonary hypertension

A. Peacock, K. Blyth
{"title":"Imaging the right ventricle in pulmonary hypertension","authors":"A. Peacock, K. Blyth","doi":"10.4103/0974-6013.54760","DOIUrl":null,"url":null,"abstract":"DOI: 10.4103/0974-6013.54760 but heavily trabeculated. It is a low-pressure volume pump, working against a resting pulmonary vascular resistance (PVR), which is only one-fifteenth of normal systemic vascular resistance. The thin-wall, anterior, midline orientation, and complex geometry of the RV pose particular challenges for all imaging methods. The techniques that have been used with considerable success in PH patients are echocardiography (including 3-dimensional echocardiography and Tissue Doppler Imaging), cardiac magnetic resonance (CMR) imaging and cardiac computed tomography (CT) imaging.","PeriodicalId":426486,"journal":{"name":"Pvri Review","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pvri Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0974-6013.54760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

DOI: 10.4103/0974-6013.54760 but heavily trabeculated. It is a low-pressure volume pump, working against a resting pulmonary vascular resistance (PVR), which is only one-fifteenth of normal systemic vascular resistance. The thin-wall, anterior, midline orientation, and complex geometry of the RV pose particular challenges for all imaging methods. The techniques that have been used with considerable success in PH patients are echocardiography (including 3-dimensional echocardiography and Tissue Doppler Imaging), cardiac magnetic resonance (CMR) imaging and cardiac computed tomography (CT) imaging.
肺动脉高压患者右心室成像
DOI: 10.4103/0974-6013.54760,但受到严重干扰。它是一个低压容积泵,在静止肺血管阻力(PVR)下工作,PVR仅为正常全身血管阻力的十五分之一。RV的薄壁、前部、中线定位和复杂的几何形状对所有成像方法都提出了特别的挑战。超声心动图(包括三维超声心动图和组织多普勒成像)、心脏磁共振(CMR)成像和心脏计算机断层扫描(CT)成像已经在PH患者中取得了相当大的成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信