Air-core inductive current sensor for fast transients measurements in distribution networks

L. Kutt, M. Shafiq, J. Jarvik, M. Lehtonen, J. Kilter
{"title":"Air-core inductive current sensor for fast transients measurements in distribution networks","authors":"L. Kutt, M. Shafiq, J. Jarvik, M. Lehtonen, J. Kilter","doi":"10.1109/PQ.2012.6256234","DOIUrl":null,"url":null,"abstract":"Observation of fast transients in power networks can provide some of the most valuable information. The transients from partial discharge can provide the information about the power line insulation state; fault-produced fast transients can also provide information about the fault or problematic section location. For measurement of fast transients, there would also need to be a very fast sensor, as the pulsed measurements could require the bandwidth range reaching in the tens of MHz range. In this paper, a sensor for fast transients measurements is presented and tested. While very simple, this sensor can offer very good performance while being inexpensive and robust. The results of performance verification measurements show very good results when testing with high-frequency pulse source, presenting the potential of such sensor.","PeriodicalId":185013,"journal":{"name":"2012 Electric Power Quality and Supply Reliability","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Electric Power Quality and Supply Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2012.6256234","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Observation of fast transients in power networks can provide some of the most valuable information. The transients from partial discharge can provide the information about the power line insulation state; fault-produced fast transients can also provide information about the fault or problematic section location. For measurement of fast transients, there would also need to be a very fast sensor, as the pulsed measurements could require the bandwidth range reaching in the tens of MHz range. In this paper, a sensor for fast transients measurements is presented and tested. While very simple, this sensor can offer very good performance while being inexpensive and robust. The results of performance verification measurements show very good results when testing with high-frequency pulse source, presenting the potential of such sensor.
用于配电网快速瞬态测量的空芯电感电流传感器
对电网快速暂态的观测可以提供一些最有价值的信息。局部放电的暂态可以提供电力线绝缘状态的信息;故障产生的快速瞬变也可以提供有关故障或有问题的部分位置的信息。对于快速瞬变的测量,还需要一个非常快的传感器,因为脉冲测量可能要求带宽范围达到数十兆赫兹范围。本文介绍了一种用于快速瞬态测量的传感器,并进行了测试。虽然非常简单,但这种传感器可以提供非常好的性能,同时价格低廉且坚固耐用。性能验证测量结果表明,在高频脉冲源的测试中,该传感器取得了很好的效果,充分展示了该传感器的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信