{"title":"High efficiency flocculation treatment of gas washing wastewater from iron and steel plant","authors":"Mei Liu, Yongbo Su","doi":"10.1109/CECNET.2011.5768377","DOIUrl":null,"url":null,"abstract":"A chemical coagulatory coprecipitation method was used in the treatment of blast-furnace gas washing water. The treatment of gas washing wasterwater from iron and steel plant with polymeric aluminum-calcium chloride coagulation and coprecipitation united with PAM, at the same time the optimum quantity of agents and process conditions to treat such wastewater through experiments is established. The optimum quantity of poly-aluminum calcium chloride is 0.33 mg/L, PAM is 0.005 mg/L, the optimum stirring time is 60s and the optimum stirring speed is 90 r/min. It is efficient to treat such wasterwater and can meet reuse standard (<100 mg/L). The cost is low and worthy to be popularized.","PeriodicalId":375482,"journal":{"name":"2011 International Conference on Consumer Electronics, Communications and Networks (CECNet)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Consumer Electronics, Communications and Networks (CECNet)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CECNET.2011.5768377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A chemical coagulatory coprecipitation method was used in the treatment of blast-furnace gas washing water. The treatment of gas washing wasterwater from iron and steel plant with polymeric aluminum-calcium chloride coagulation and coprecipitation united with PAM, at the same time the optimum quantity of agents and process conditions to treat such wastewater through experiments is established. The optimum quantity of poly-aluminum calcium chloride is 0.33 mg/L, PAM is 0.005 mg/L, the optimum stirring time is 60s and the optimum stirring speed is 90 r/min. It is efficient to treat such wasterwater and can meet reuse standard (<100 mg/L). The cost is low and worthy to be popularized.
炼钢厂洗气废水的高效絮凝处理
采用化学混凝共沉淀法处理高炉煤气洗涤水。采用聚合氯化铝-氯化钙混凝共沉淀法联合PAM处理炼钢厂洗气废水,同时通过实验确定了处理该类废水的最佳药剂用量和工艺条件。聚铝氯化钙的最佳用量为0.33 mg/L, PAM为0.005 mg/L,最佳搅拌时间为60s,最佳搅拌速度为90 r/min。废水处理效率高,可达到回用标准(< 100mg /L)。成本低,值得推广。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信