Three dimensional shape measurement system for residual ridges.

T Morimitsu, T Nokubi, T Ono, K Watanabe, M Kibi, Y Okuno
{"title":"Three dimensional shape measurement system for residual ridges.","authors":"T Morimitsu,&nbsp;T Nokubi,&nbsp;T Ono,&nbsp;K Watanabe,&nbsp;M Kibi,&nbsp;Y Okuno","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>It is very important for design and construction of complete dentures to evaluate the condition of residual ridges of edentulous patients objectively and precisely. The authors have been developing a shape measurement system for residual ridges. In this study, the outline of the system is described and the accuracy of the system is evaluated. The system consists of a high precision laser displacement meter, a working table and its controller, and a personal computer. The working table, on which a plaster model is placed, can move until the end of the moving range at a speed of 0.7 mm/sec. The height of the plaster model was measured intermittently with a frequency of 7 points/sec. To determine the accuracy of this system, experimental plaster models, which simulated the simplified shape of residual ridge, were measured and analyzed. The measurement error was 2.5%, which seemed to be highly accurate. The accuracy of the measurement decreased with the darkness of the color of the plaster model.</p>","PeriodicalId":76655,"journal":{"name":"The Journal of Osaka University Dental School","volume":"32 ","pages":"97-103"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Osaka University Dental School","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It is very important for design and construction of complete dentures to evaluate the condition of residual ridges of edentulous patients objectively and precisely. The authors have been developing a shape measurement system for residual ridges. In this study, the outline of the system is described and the accuracy of the system is evaluated. The system consists of a high precision laser displacement meter, a working table and its controller, and a personal computer. The working table, on which a plaster model is placed, can move until the end of the moving range at a speed of 0.7 mm/sec. The height of the plaster model was measured intermittently with a frequency of 7 points/sec. To determine the accuracy of this system, experimental plaster models, which simulated the simplified shape of residual ridge, were measured and analyzed. The measurement error was 2.5%, which seemed to be highly accurate. The accuracy of the measurement decreased with the darkness of the color of the plaster model.

残脊三维形状测量系统。
客观准确地评估无牙患者残牙脊的状况,对全口义齿的设计和制作具有重要意义。作者一直在开发一种残脊形状测量系统。在本研究中,描述了系统的轮廓,并对系统的准确性进行了评估。该系统由高精度激光位移计、工作台及其控制器和个人计算机组成。放置石膏模型的工作台可以以0.7毫米/秒的速度移动到移动范围的末端。以7点/秒的频率间歇测量石膏模型高度。为了确定该系统的准确性,对模拟残脊简化形状的实验石膏模型进行了测量和分析。测量误差为2.5%,这似乎是非常准确的。测量的准确性随着石膏模型颜色的暗度而下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信