{"title":"Solving the multiobjective environmental/economic dispatch problem with prohibited operating zones using NSGA-II","authors":"R. King, H. Rughooputh, K. Deb","doi":"10.1109/PACRIM.2011.6032909","DOIUrl":null,"url":null,"abstract":"A thermal or hydro generating unit may have prohibited operating zones due to physical limitations of power plant components caused, for example, by vibrations in a shaft bearing which are amplified in a certain operating region. In this case, the unit can only operate above or below the prohibited operating zone. The effect of prohibited operating zones on the multiobjective environmental/economic dispatch problem is investigated in this paper. The IEEE 30-bus system with transmission losses has been considered with prohibited operating zones and simulation performed using the elitist Nondominated Sorting Genetic Algorithm (NSGA-II) for two constraint handling methods, namely penalty parameterless and decoder-based approaches. Simulation results show that both methods can equally handle this particular scenario in the environmental/economic dispatch problem. Different number of prohibited operating zones was considered for the six generators in the system yielding discontinuous and non-convex non-dominated fronts.","PeriodicalId":236844,"journal":{"name":"Proceedings of 2011 IEEE Pacific Rim Conference on Communications, Computers and Signal Processing","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2011 IEEE Pacific Rim Conference on Communications, Computers and Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PACRIM.2011.6032909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
Abstract
A thermal or hydro generating unit may have prohibited operating zones due to physical limitations of power plant components caused, for example, by vibrations in a shaft bearing which are amplified in a certain operating region. In this case, the unit can only operate above or below the prohibited operating zone. The effect of prohibited operating zones on the multiobjective environmental/economic dispatch problem is investigated in this paper. The IEEE 30-bus system with transmission losses has been considered with prohibited operating zones and simulation performed using the elitist Nondominated Sorting Genetic Algorithm (NSGA-II) for two constraint handling methods, namely penalty parameterless and decoder-based approaches. Simulation results show that both methods can equally handle this particular scenario in the environmental/economic dispatch problem. Different number of prohibited operating zones was considered for the six generators in the system yielding discontinuous and non-convex non-dominated fronts.