Mitigation of power supply disturbance in electronic loads

K. Basu, N. M. Nor, S. A. Hafidz
{"title":"Mitigation of power supply disturbance in electronic loads","authors":"K. Basu, N. M. Nor, S. A. Hafidz","doi":"10.1109/ICEAS.2011.6147127","DOIUrl":null,"url":null,"abstract":"An alternate power supply guarantees the performance of loads during voltage disturbances in the normal supply. It is proposed to implement a quick change over of the power supply of single-phase electronic loads from the faulty phase to a healthy phase in a 3-phase system. Super capacitors maintain the dc voltage during the period of disturbance. A zigzag transformer may also be used to rebuild a balanced 3-phase load voltage by isolating the faulty phase from the load. Both the 3-phase and single-phase loads may be supplied with the rated voltage during the period of disturbance. Use of a static transfer switch reduces the change over time to 0.02 second.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An alternate power supply guarantees the performance of loads during voltage disturbances in the normal supply. It is proposed to implement a quick change over of the power supply of single-phase electronic loads from the faulty phase to a healthy phase in a 3-phase system. Super capacitors maintain the dc voltage during the period of disturbance. A zigzag transformer may also be used to rebuild a balanced 3-phase load voltage by isolating the faulty phase from the load. Both the 3-phase and single-phase loads may be supplied with the rated voltage during the period of disturbance. Use of a static transfer switch reduces the change over time to 0.02 second.
电子负载中电源干扰的缓解
备用电源保证在正常电源电压扰动时负载的性能。提出了在三相系统中实现单相电子负载电源从故障相到健康相的快速转换。超级电容器在扰动期间保持直流电压。锯齿形变压器也可用于通过将故障相与负载隔离来重建平衡的三相负载电压。在扰动期间,三相和单相负载都可以用额定电压供电。使用静态转换开关将随时间的变化减少到0.02秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信