[A case of hepatoma patient who showed an abnormally high level of serum IRI with the beads method].

Igaku kenkyu. Acta medica Pub Date : 1992-02-01
T Kamada, R Kisanuki, T Nishimura, M Masumitsu, K Shiraishi, G Tanabe, H Shimazu, S Otsuji
{"title":"[A case of hepatoma patient who showed an abnormally high level of serum IRI with the beads method].","authors":"T Kamada,&nbsp;R Kisanuki,&nbsp;T Nishimura,&nbsp;M Masumitsu,&nbsp;K Shiraishi,&nbsp;G Tanabe,&nbsp;H Shimazu,&nbsp;S Otsuji","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A fifty four years old hepatoma patient admitted to the hospital for a surgical operation. Preoperative laboratory examination demonstrated that his serum IRI level was very high (423 microU/ml) when measured with a beads method, however RIA or a microplate method demonstrated normal values. We studied the mechanism of the discrepancy of IRI values. 1) Both the beads and microplate methods demonstrated the same IRI values when the patient's serum insulin was roughly purified with Sep-Pak. The beads method showed high IRI values in serum which passed through Sep-Pak, therefore contained no insulin. 2) The similar results were observed when the patient's serum fractionated by a gel-chromatography (Biogel P-30). The beads method demonstrated high IRI values in both insulin fractions and the fractions containing serum proteins bigger than 40,000 molecular weight. The microplate method demonstrated only one large peak of insulin. 3) When non-specific IgG of guinea pig was used as a fixed antibody instead of human insulin antibody of guinea pig that was used in the beads method, the patient's serum showed the similar values as that obtained with the beads method. We thereby concluded that the abnormal level of IRI by the beads method was derived from the unknown substance reacting with IgG of guinea pig in the patient's serum. After the surgical resection of hepatoma, the levels of IRI measured by the beads method decreased significantly, suggesting that the substance is related to hepatoma cells.</p>","PeriodicalId":13473,"journal":{"name":"Igaku kenkyu. Acta medica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Igaku kenkyu. Acta medica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A fifty four years old hepatoma patient admitted to the hospital for a surgical operation. Preoperative laboratory examination demonstrated that his serum IRI level was very high (423 microU/ml) when measured with a beads method, however RIA or a microplate method demonstrated normal values. We studied the mechanism of the discrepancy of IRI values. 1) Both the beads and microplate methods demonstrated the same IRI values when the patient's serum insulin was roughly purified with Sep-Pak. The beads method showed high IRI values in serum which passed through Sep-Pak, therefore contained no insulin. 2) The similar results were observed when the patient's serum fractionated by a gel-chromatography (Biogel P-30). The beads method demonstrated high IRI values in both insulin fractions and the fractions containing serum proteins bigger than 40,000 molecular weight. The microplate method demonstrated only one large peak of insulin. 3) When non-specific IgG of guinea pig was used as a fixed antibody instead of human insulin antibody of guinea pig that was used in the beads method, the patient's serum showed the similar values as that obtained with the beads method. We thereby concluded that the abnormal level of IRI by the beads method was derived from the unknown substance reacting with IgG of guinea pig in the patient's serum. After the surgical resection of hepatoma, the levels of IRI measured by the beads method decreased significantly, suggesting that the substance is related to hepatoma cells.

[用珠子法检测异常高水平IRI的肝癌患者1例]。
一名54岁的肝癌患者入院接受外科手术。术前实验室检查显示患者血清IRI水平非常高(423微u /ml),用微珠法测定,但RIA或微孔板法显示正常值。我们研究了IRI值差异的机制。1)用Sep-Pak粗略纯化患者血清胰岛素时,珠球法和微孔板法的IRI值相同。小球法在通过Sep-Pak的血清中显示高IRI值,因此不含胰岛素。2)用凝胶层析(Biogel P-30)对患者血清进行分离时,也观察到类似的结果。小球法在胰岛素组分和含有大于40,000分子量的血清蛋白的组分中均显示出高IRI值。微孔板法显示胰岛素只有一个大峰。3)用豚鼠非特异性IgG作为固定抗体代替珠粒法使用的豚鼠人胰岛素抗体时,患者血清显示出与珠粒法相似的值。因此,我们认为小珠法检测到的IRI水平异常是由于患者血清中未知物质与豚鼠IgG反应所致。肝癌手术切除后,用小珠法测定的IRI水平明显下降,提示该物质与肝癌细胞有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信