Data acquisition and protection system for a multi-MHz neutron detector

M. Drochner, H. Kleines, R. Moller, A. Radulescu, M. Delong, D. McCormick
{"title":"Data acquisition and protection system for a multi-MHz neutron detector","authors":"M. Drochner, H. Kleines, R. Moller, A. Radulescu, M. Delong, D. McCormick","doi":"10.1109/RTC.2016.7543114","DOIUrl":null,"url":null,"abstract":"At the “KWS2” small angle scattering instrument at the “FRM-2” neutron source at Garching, Germany a new 3He neutron detector was installed and commissioned in 2015. It is built of 18 “8-pack” modules from GE Power / Reuter-Stokes. Each of these modules has its own data acquisition and slow control processor, using only Gigabit Ethernet as its connection to the outside world. We show how data acquisition, time synchronization and interaction with the slow control system are laid out, as well as some first results and performance data.","PeriodicalId":383702,"journal":{"name":"2016 IEEE-NPSS Real Time Conference (RT)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE-NPSS Real Time Conference (RT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTC.2016.7543114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

At the “KWS2” small angle scattering instrument at the “FRM-2” neutron source at Garching, Germany a new 3He neutron detector was installed and commissioned in 2015. It is built of 18 “8-pack” modules from GE Power / Reuter-Stokes. Each of these modules has its own data acquisition and slow control processor, using only Gigabit Ethernet as its connection to the outside world. We show how data acquisition, time synchronization and interaction with the slow control system are laid out, as well as some first results and performance data.
多兆赫中子探测器数据采集与保护系统
2015年,在德国Garching“FRM-2”中子源的“KWS2”小角散射仪上安装了一台新的3He中子探测器并投入使用。它由GE Power / reuters - stokes提供的18个“8包”模块组成。每个模块都有自己的数据采集和慢速控制处理器,仅使用千兆以太网作为与外部世界的连接。我们展示了如何进行数据采集、时间同步和与慢速控制系统的交互,以及一些初步结果和性能数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信