Quantitative image reconstruction using position-dependent scatter correction in single photon emission CT

K. Ogawa, A. Chugo, T. Ichihara, A. Kubo, S. Hashimoto
{"title":"Quantitative image reconstruction using position-dependent scatter correction in single photon emission CT","authors":"K. Ogawa, A. Chugo, T. Ichihara, A. Kubo, S. Hashimoto","doi":"10.1109/NSSMIC.1992.301459","DOIUrl":null,"url":null,"abstract":"Elimination of scattered photons from acquired counts is necessary for reconstructing a quantitative SPECT (single photon emission computed tomography) image. To perform correction of the scattered photons, the authors have developed a novel scatter correction method considering the local scatter fraction at each pixel in a planar image and evaluated its validity by simulations using numerical phantoms. In the present work, they evaluate the parameters used in the correction method, i.e., the width of a main window and subwindows, and the location of the subwindows. They show the results of experiments using a myocardial phantom and preliminary clinical studies using a commercially available gamma-camera system equipped with special hardware. In the clinical studies, a new Tc-99m myocardial perfusion imaging agent (P-53) was used. These results show that quantitative measurement of activity in clinical study is possible without adding data acquisition/processing time.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Elimination of scattered photons from acquired counts is necessary for reconstructing a quantitative SPECT (single photon emission computed tomography) image. To perform correction of the scattered photons, the authors have developed a novel scatter correction method considering the local scatter fraction at each pixel in a planar image and evaluated its validity by simulations using numerical phantoms. In the present work, they evaluate the parameters used in the correction method, i.e., the width of a main window and subwindows, and the location of the subwindows. They show the results of experiments using a myocardial phantom and preliminary clinical studies using a commercially available gamma-camera system equipped with special hardware. In the clinical studies, a new Tc-99m myocardial perfusion imaging agent (P-53) was used. These results show that quantitative measurement of activity in clinical study is possible without adding data acquisition/processing time.<>
基于位置相关散射校正的单光子发射CT定量图像重建
从获得的计数中消除散射光子是重建定量SPECT(单光子发射计算机断层扫描)图像所必需的。为了对散射光子进行校正,作者提出了一种新的散射校正方法,该方法考虑了平面图像中每个像素的局部散射分数,并通过数值模拟评估了其有效性。在本工作中,他们评估了校正方法中使用的参数,即主窗口和子窗口的宽度以及子窗口的位置。他们展示了使用心肌幻像的实验结果,以及使用配备特殊硬件的商用伽马相机系统进行初步临床研究的结果。在临床研究中,使用了一种新的Tc-99m心肌灌注显像剂(P-53)。这些结果表明,在不增加数据采集/处理时间的情况下,临床研究中活性的定量测量是可能的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信