K. Ogawa, A. Chugo, T. Ichihara, A. Kubo, S. Hashimoto
{"title":"Quantitative image reconstruction using position-dependent scatter correction in single photon emission CT","authors":"K. Ogawa, A. Chugo, T. Ichihara, A. Kubo, S. Hashimoto","doi":"10.1109/NSSMIC.1992.301459","DOIUrl":null,"url":null,"abstract":"Elimination of scattered photons from acquired counts is necessary for reconstructing a quantitative SPECT (single photon emission computed tomography) image. To perform correction of the scattered photons, the authors have developed a novel scatter correction method considering the local scatter fraction at each pixel in a planar image and evaluated its validity by simulations using numerical phantoms. In the present work, they evaluate the parameters used in the correction method, i.e., the width of a main window and subwindows, and the location of the subwindows. They show the results of experiments using a myocardial phantom and preliminary clinical studies using a commercially available gamma-camera system equipped with special hardware. In the clinical studies, a new Tc-99m myocardial perfusion imaging agent (P-53) was used. These results show that quantitative measurement of activity in clinical study is possible without adding data acquisition/processing time.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
Elimination of scattered photons from acquired counts is necessary for reconstructing a quantitative SPECT (single photon emission computed tomography) image. To perform correction of the scattered photons, the authors have developed a novel scatter correction method considering the local scatter fraction at each pixel in a planar image and evaluated its validity by simulations using numerical phantoms. In the present work, they evaluate the parameters used in the correction method, i.e., the width of a main window and subwindows, and the location of the subwindows. They show the results of experiments using a myocardial phantom and preliminary clinical studies using a commercially available gamma-camera system equipped with special hardware. In the clinical studies, a new Tc-99m myocardial perfusion imaging agent (P-53) was used. These results show that quantitative measurement of activity in clinical study is possible without adding data acquisition/processing time.<>