Reduced order controller for FO-IMC with desired phase margin and gain cross-over frequency

Pushkar Prakash Arya, S. Chakrabarty
{"title":"Reduced order controller for FO-IMC with desired phase margin and gain cross-over frequency","authors":"Pushkar Prakash Arya, S. Chakrabarty","doi":"10.1109/IBSSC47189.2019.8973036","DOIUrl":null,"url":null,"abstract":"Fractional order (FO) controller provide more number of tuning parameters than integer order (IO) counterpart. In this paper, a fractional order (FO) internal model control (IMC) is considered which provides two tuning parameters $(\\lambda$ and $\\beta)$ as compared to integer order (IO) counterpart. These two parameters are tuned to get the desired $\\varphi_{m}$ and $\\omega_{g}$ for higher order systems. Usually, we use IO approximation of FO terms in the controllers. It is observed that 5-15 order IO approximation provide almost accurate behavior for the FO terms. The problem with such approximation is the resulting higher order controller. In this work, a balanced truncation method is used to get a reduced order controller which retains important properties of higher order controller. The viability of reduced order controller is measured in terms of maximum sensitivity $(M_{s})$ and the frequency at which the system is most sensitive $(\\omega_{m})$. Further, the results are compared in terms of rise time $(T_{r})$, settling time $(T_{s})$, maximum overshoot (%$M)$, integral square error (ISE), integral absolute error (IAE) and integral of the time weighted absolute error (ITAE). The importance of using reduced order controller is checked using three examples: first, a minimum phase (MP) system, second, a non-minimum phase (NMP) system with right hand plane (RHP) zero and third, a first order plus time delay (FOPTD) system. It is observed that the lower order controller can be used for higher order controller.","PeriodicalId":148941,"journal":{"name":"2019 IEEE Bombay Section Signature Conference (IBSSC)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Bombay Section Signature Conference (IBSSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBSSC47189.2019.8973036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Fractional order (FO) controller provide more number of tuning parameters than integer order (IO) counterpart. In this paper, a fractional order (FO) internal model control (IMC) is considered which provides two tuning parameters $(\lambda$ and $\beta)$ as compared to integer order (IO) counterpart. These two parameters are tuned to get the desired $\varphi_{m}$ and $\omega_{g}$ for higher order systems. Usually, we use IO approximation of FO terms in the controllers. It is observed that 5-15 order IO approximation provide almost accurate behavior for the FO terms. The problem with such approximation is the resulting higher order controller. In this work, a balanced truncation method is used to get a reduced order controller which retains important properties of higher order controller. The viability of reduced order controller is measured in terms of maximum sensitivity $(M_{s})$ and the frequency at which the system is most sensitive $(\omega_{m})$. Further, the results are compared in terms of rise time $(T_{r})$, settling time $(T_{s})$, maximum overshoot (%$M)$, integral square error (ISE), integral absolute error (IAE) and integral of the time weighted absolute error (ITAE). The importance of using reduced order controller is checked using three examples: first, a minimum phase (MP) system, second, a non-minimum phase (NMP) system with right hand plane (RHP) zero and third, a first order plus time delay (FOPTD) system. It is observed that the lower order controller can be used for higher order controller.
具有期望相位裕度和增益交叉频率的FO-IMC降阶控制器
分数阶(FO)控制器比整数阶(IO)控制器提供更多的调优参数。本文考虑了分数阶(FO)内模控制(IMC),与整数阶(IO)内模控制相比,IMC提供了两个调优参数$(\lambda$和$\beta)$。对这两个参数进行调优,以获得更高阶系统所需的$\varphi_{m}$和$\omega_{g}$。通常,我们在控制器中使用IO逼近FO项。观察到,5-15阶IO近似为FO项提供了几乎准确的行为。这种近似的问题是产生的高阶控制器。本文采用平衡截断法得到了保留高阶控制器重要特性的降阶控制器。降阶控制器的可行性是根据最大灵敏度$(M_{s})$和系统最敏感的频率$(\omega_{m})$来衡量的。进一步比较了上升时间$(T_{r})$、沉降时间$(T_{s})$、最大超调量(%$M)$, integral square error (ISE), integral absolute error (IAE) and integral of the time weighted absolute error (ITAE). The importance of using reduced order controller is checked using three examples: first, a minimum phase (MP) system, second, a non-minimum phase (NMP) system with right hand plane (RHP) zero and third, a first order plus time delay (FOPTD) system. It is observed that the lower order controller can be used for higher order controller.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信