{"title":"Improved dfig dftc by using a fractional-order super twisting algorithms in wind power application","authors":"A. Almakki, Andrey Mazalov","doi":"10.17816/transsyst202173131-149","DOIUrl":null,"url":null,"abstract":"Background: The direct flux and torque control are a robust, simple, and alternative approach control formulation that does not require decomposition into symmetrical components; the direct flux and torque control schemes have been proved to be preponderant for doubly-fed induction generators due to the simple implementation. \nAim: This work presents the minimization of electromagnetic torque and rotor flux undulations of doubly-fed induction generators using fractional-order super twisting algorithms and modified space vector modulation techniques. \nMethods: The main role of direct flux and torque control is to regulate and control the electromagnetic torque and rotor flux of doubly-fed induction generators for wind turbine systems. The direct flux and torque control is a traditional control algorithm and robust technique. Fractional-order super twisting algorithms are a new and proposed nonlinear controller; characterized by a robust controller and a simpler algorithm, which gives a good harmonic distortion of current compared to other methods. \nNovelty: The A fractional-order super twisting algorithm is proposed. Proposed nonlinear controller construction is based on the traditional super twisting algorithm and fractional calculus to obtain a robust controller and reduces the electromagnetic torque and rotor flux undulations of doubly-fed induction generators. We use in our study a 1.5 MW doubly-fed induction generator integrated into a single-rotor wind turbine system to minimizes the electromagnetic torque, stator current, rotor flux undulations. As shown in the results figures using fractional-order super twisting algorithms ameliorate effectiveness especially minimizes the electromagnetic torque and rotor flux, and minimizes harmonic distortion of stator current (0.16 %) compared to the traditional control scheme. \nResults: As shown in the results figures using fractional-order super twisting algorithms ameliorate effectiveness especially minimizes the electromagnetic torque and rotor flux, and minimizes harmonic distortion of stator current (0.16 %) compared to the traditional control scheme. \nConclusion: The direct flux and torque control are a robust, simple, and alternative approach control formulation that does not require decomposition into symmetrical components; the direct flux and torque control schemes have been proved to be preponderant for doubly-fed induction generators due to the simple implementation.","PeriodicalId":255036,"journal":{"name":"Modern Transportation Systems and Technologies","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern Transportation Systems and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/transsyst202173131-149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Background: The direct flux and torque control are a robust, simple, and alternative approach control formulation that does not require decomposition into symmetrical components; the direct flux and torque control schemes have been proved to be preponderant for doubly-fed induction generators due to the simple implementation. Aim: This work presents the minimization of electromagnetic torque and rotor flux undulations of doubly-fed induction generators using fractional-order super twisting algorithms and modified space vector modulation techniques. Methods: The main role of direct flux and torque control is to regulate and control the electromagnetic torque and rotor flux of doubly-fed induction generators for wind turbine systems. The direct flux and torque control is a traditional control algorithm and robust technique. Fractional-order super twisting algorithms are a new and proposed nonlinear controller; characterized by a robust controller and a simpler algorithm, which gives a good harmonic distortion of current compared to other methods. Novelty: The A fractional-order super twisting algorithm is proposed. Proposed nonlinear controller construction is based on the traditional super twisting algorithm and fractional calculus to obtain a robust controller and reduces the electromagnetic torque and rotor flux undulations of doubly-fed induction generators. We use in our study a 1.5 MW doubly-fed induction generator integrated into a single-rotor wind turbine system to minimizes the electromagnetic torque, stator current, rotor flux undulations. As shown in the results figures using fractional-order super twisting algorithms ameliorate effectiveness especially minimizes the electromagnetic torque and rotor flux, and minimizes harmonic distortion of stator current (0.16 %) compared to the traditional control scheme. Results: As shown in the results figures using fractional-order super twisting algorithms ameliorate effectiveness especially minimizes the electromagnetic torque and rotor flux, and minimizes harmonic distortion of stator current (0.16 %) compared to the traditional control scheme. Conclusion: The direct flux and torque control are a robust, simple, and alternative approach control formulation that does not require decomposition into symmetrical components; the direct flux and torque control schemes have been proved to be preponderant for doubly-fed induction generators due to the simple implementation.
采用分数阶超扭转算法改进了dfig dftc在风力发电中的应用
背景:直接磁链和转矩控制是一种鲁棒、简单和替代的方法控制公式,不需要分解成对称的组件;直接磁链和转矩控制方案由于实现简单而被证明是双馈感应发电机的优势。目的:利用分数阶超扭转算法和改进的空间矢量调制技术,实现双馈感应发电机电磁转矩和转子磁链波动的最小化。方法:直接磁链和转矩控制的主要作用是调节和控制风力发电系统双馈感应发电机的电磁转矩和转子磁链。直接磁链和转矩控制是传统的控制算法和鲁棒技术。分数阶超扭转算法是一种新的非线性控制器。与其他方法相比,该方法具有鲁棒控制器和简单算法的特点,具有良好的电流谐波畸变。新颖:提出了一种分数阶超扭转算法。提出了基于传统超扭转算法和分数阶微积分的非线性控制器结构,以获得鲁棒控制器,减小双馈感应发电机的电磁转矩和转子磁链波动。在我们的研究中,我们将1.5 MW双馈感应发电机集成到一个单转子风力涡轮机系统中,以最小化电磁转矩,定子电流,转子磁链波动。结果如图所示,与传统控制方案相比,分数阶超扭算法改善了效率,特别是使电磁转矩和转子磁链最小,使定子电流谐波畸变最小(0.16%)。结果如图所示,与传统控制方案相比,分数阶超扭算法改善了效率,特别是使电磁转矩和转子磁链最小,使定子电流谐波畸变最小(0.16%)。结论:直接磁链和转矩控制是一种鲁棒、简单、可替代的方法控制公式,不需要分解成对称分量;直接磁链和转矩控制方案由于实现简单而被证明是双馈感应发电机的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信